Numerical Display
KEYPAD CONTROLS AND INDICATORS
l
Flashes number(s) - indicates which non-24-Hour Zones are in an alarm condition, and
which Day Zones are in a trouble condition.
l
Flashes
“P”
(with steady sounder) - indicates a Priority condition (armed with a Priority
Zone in trouble, armed without resetting a Day
Z
one, or armed with out ac power available
to the system).
Armed (Red) Light
l
Steady - system is armed.
ZONE
l
Flashes - alarm on a non-24-Hour Zone.
l
Flashes (fast) - entry delay cancelled.
Ready (Green) Light
Ready
l
Steady - system disarmed, all non-24-Hour Zones okay.
Bypass
l
Flashes - trouble on any non-24-Hour Zone.
l
Flashes (fast) - trouble on a Day Zone.
Bypass (Yellow) Light
l
Steady - one or more zones manually bypassed.
Sounder
(To stop sounder “trouble” warnings, hold down Key [9] for 2 seconds.)
l
Steady Tone: A Priority condition exists.
l
Steady Tone (when entering): Entry delay in progress.
l
Beep (3 second): “Door Chime” feature on Zone 1.
l
Beep (2 seconds): System armed with a zone in trouble.
l
Pulsing: Day Zone is in trouble.
KEYS
Note:
Unless otherwise noted, the following numerical keys are held down for 2 seconds (until
sounder beeps) to perform their designated hold-down functions.
Key [1]: TEST -
Momentarily sounds the burglar alarm. If no alarm is heard, or if it is weak,
the battery may need replacing. Use this test weekly. (Hold key down until beep sounds.)
Key [2]: DISPLAY BYPASS -
Numerically displays zones that have been bypassed. (Hold key
down until all zones have been displayed.)
Key [3]: DISPLAY ZONES OPEN -
Numerically displays zone(s) in trouble. (Hold key down
until all zones have been displayed.)
Key [4]: INSTANT PROTECTION -
Cancels entry delay when arming. The delay is restored
after you disarm the system. (Hold key down until beep sounds.)
Key [5]: ONE-BUTTON ARMING
(If Programmed) - Momentary press permits quick arming.
(Disarming still requires entry of the complete code.)
Key [6]: DOOR CHIME-This
will activate a feature that sounds a 3-second tone at the keypad
each time the entry door on Zone 1 is opened. This feature only works when the alarm system
is disarmed (off). To deactivate the door chime, hold Key [6] down again until the beep sounds.
Key
[8]: PROGRAM -
Allows you to enter the program mode. Hold down Key
[8]
until the
beep sounds. See
PROGRAMMING.
Key [9]:
RESET
- Resets ac power loss indication. Also, clears numerical display after alarm
and system disarmed. (Hold down until beep sounds.)
Key
[B]:
BYPASS -
Momentarily
press Key
[B]
to manually bypass a zone. See
Arming With
Selective Zone Bypassing.
Keys [*] and [#]: PANIC BUTTONS -
Pressing these two keys
momentarily
will activate the
Panic Zone. Also used to exit the Program mode.