background image

ALPCI2-U 

 

PC to Digital Lock Interface 

 

INSTALLATION  INSTRUCTIONS

 

GENERAL DESCRIPTION 

The ALPCI2-U is an interface cable that allows high speed 

communication between a PC running DL-Windows software 
and a compatible Trilogy Digital Lock, Data Transfer Module, 
or an AL-PRE proximity card reader.  Using the ALPCI2-U, 
the PC can upload or download programming to/from the 
lock, and upload event history.  

 

 
 

Compatible Trilogy Digital Locks: 

 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

SPECIFICATIONS 

Input Power:  Supplied by the PC and lock connections 
Dimensions:  2 

5

/

8

"L x 1¼"H x ¾"W with 5' cord 

 

SYSTEM REQUIREMENTS 

IBM PC or compatible desktop or notebook computer with 
233 MHz or faster processor.  

At least 10 Mb available on hard drive 

At least 64 MB of RAM memory 

Microsoft Windows 95, 98, NT4.0 or higher  

DL-Windows 

One unused RS-232 Serial Communications port (Com 1–
4), or USB Port (see NOTE 1). 

 

OPERATION 

For details regarding the use of the ALPCI2-U, refer to DL-
Windows User Guide OI237.

 

NOTE 2:

 

 

The ALPCI2-U is designed to be used on a 9 pin serial 
Com Port.  If your computer has a 25 pin Com Port, a 
25 pin to 9 pin adapter must be used.  

Warning:

 

Polarity MUST be observed when connecting to the 
lock.  The tab (–) must plug into the left hole (black).  

Trilogy

®

 is a registered trademark of Alarm Lock.                                                                                                                                    Windows is a trademark of Microsoft  

NOTE 1:

 

 

The ALPCI2-U is fully RS-232 compliant and will function prop-
erly with a computer that has an RS-232 compliant serial Com 
Port.  However, many new notebook computers do not provide 
the proper RS-232 compatible Com Port voltage levels re-
quired by the ALPCI2-U.  In these cases, the ALPCI2-U may 
not function properly.  

 

To test a serial Com Port for ALPCI2-U compatibility, attach the 
ALPCI2-U to the Com Port and run the DL-Windows loop-back 
test.  If the loop-back test fails, the Com Port is most likely not 
RS-232 complaint.  

 

For new computers with non-RS232 compliant Com Ports, it is 
recommended that the ALPCI2-U be connected to the com-
puter’s USB port using the supplied USB converter (MX1130) 
from Alarm Lock Systems. The MX1130 has been fully tested 
by Alarm Lock for use with the ALPCI2-U.   

 

For more information, go to the Alarm Lock website at: 

www.alarmlock.com

 or contact your distributor. 

Application 1   

Program the Lock directly using a PC or 

Laptop 

ALPCI2-U 

Application 2   

Send Trilogy Lock Programs from PC to 

AL-DTM for transfer to multiple Digital Locks OR use 
the AL-DTM to retrieve system activity reports from 
locks to be transferred to the PC. 

ALPCI2-U 

Application 3

  Connect the AL-PRE Prox Card Enroller 

to the PC to read Prox Cards directly into DL-
Windows. 

ALPCI2-U 

345 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs 1-800-ALA-LOCK 

For Technical Service 1-800-645-9440 

 

Publicly traded on NASDAQ             Symbol: NSSC

 

© ALARM LOCK 2005 

CONNECTION 

Refer to the following wiring diagrams / applications:

 

WI1478  11/05 

DL3000 

DL2800 

PDL4100 

DK3000 

DL3500 

DL4100 

DL4500 

 

PDL3000 

PDL3500 

PDL4500   

ETDL 

ETPDL 

PDK3000   

 

 