Concord 4 CDMA Module

 

|

 

Installation Guide 

Concord 4 CDMA Module

 

INSTALLATION GUIDE

 

 

Introduction                                                                           

  

The CDMA Module V4 for Concord 4 & higher enables

 

wireless reporting 

of all alarms and other system events from the

 

Interlogix Concord 4 

control panel using the CDMA wireless

 

(cellular) network. The module 

can be used as

 

the primary communication path for all alarm signaling, 

or as a backup to a

 

telephone line connection to the central monitoring 

station. The

 

wireless alarm signaling and routing service is operated by

 

Alarm.com.  The Concord 4 CDMA module also features integrated 
support for Alarm.com’s emPower

TM 

solution with built-in Z-Wave 

capabilities and is compatible with the Alarm.com Image Sensor 
(additional hardware required). 
 
The module interfaces with the Concord panel data bus and is powered 
by the panel battery or an auxiliary 12 VDC power supply.  Status LEDs 
indicate bus and cellular network communications. 

Contact Information                                                             

 

For additional information and support on Alarm.com products and 
services, please visit 

www.alarm.com/dealer

 or contact Alarm.com 

Technical Support at 1-866-834-0470. 
Copyright © 2012 Alarm.com. All rights reserved 

 

Compatibility                                                                         

 

The module can be used on Concord 4.0 and higher to enable 
Alarm.com’s interactive suite of services.   

 

Account Creation                                                                  

 

Before installing the Alarm.com CDMA Module in a Concord system, a 
new customer account needs to be created with Alarm.com. We 
recommend creating the account at least 24 hours in advance of 
installation to ensure that the radio is activated prior to installation. 
 
To activate an account go to www.alarm.com/dealer and login.  Under 
the “Customers” heading at the top left of the page click on “Create New 
Customer”. You will need the following customer information to create 
the account: 

 

Customer Name 

 

Customer Address 

 

Customer Phone Number 

 

Customer E-mail 

 

Preferred login name for the customer 

 

Alarm.com Module Serial Number 

 
At the end of the account creation process you will be able to print a 
Welcome Letter for the customer that has their login information and 
temporary password for the Alarm.com website. 

 

Installation Overview & Guidelines                                   

Before beginning the module installation, familiarize yourself with the 
following installation guidelines and the location of the module and 
troubleshooting LEDs and their function as shown in 

Figure 1 

and 

Table 

2

, as they are referenced throughout this guide.  Using these tips will 

help guarantee a successful module installation. 
 

1)

 

Create the customer account on the Alarm.com Dealer Site at least 24 
hours before installation. See 

Account Creation

 

above

2)

 

Turn off the “Access Code Lock” feature on the panel.  This feature 

MUST

 be off for the system to communicate with Alarm.com. 

3)

 

Installation consists of finding a mounting location for optimum 
wireless signal strength, mounting and wiring the module, and 
installing a case tamper (if necessary).  Use the CDMA Status LEDs on 
the module to check the signal strength before you permanently mount 
the module to avoid signaling issues after the installation is complete. 

4)

 

Power the module off of the battery, not off of the panel.  (See 

Wiring

 

on page 2.)   

    

 

5)

 

Perform a manual phone test (Comm Test) to initiate communication 
(See 

Power up

 on page 3.) 

6)

 

Observe panel power limitations as stipulated below: 

 

The module draws a maximum of 65 mA (continuous) in PowerSave 
mode and 100 mA (continuous) in Idle Mode and Connected Mode 
from the panel. The module can draw up to 1600 mA 
(instantaneous peaks) from the panel. 

 

Do not exceed the panel total output power when using panel 
power for bus devices and hardwired sensors (refer to panel 
documentation). 

 

Use four-conductor, 22 or 18 gauge stranded wire to connect the 
module to the panel. 

Table 1

 shows the maximum wire length for 

each gauge.

 

 
Table 1: Maximum wire length 

Gauge 

Maximum Wire Length 

22 gauge 

40 ft. (12.2 m) 

18 gauge 

90ft. (27.4 m) 

 
Figure 1: Main module components 

 
                         

 
 

 

 

 

 

 

Table 2: Component Descriptions 

Component

 

Function

 

PWR LED  

Indicates module power status. 

BUS LED 

Indicates data bus activity between the panel and module. 

AUTO LED 

Indicates module/data transceiver communication. 

Gateway Status 
LEDs

 

Indicates the current signal and status of the wireless gateway 
module.  (See 

Gateway Status LEDs

 on page 3 for more 

information.)

 

Wiring terminals

 

Provides wiring connection to the panel.

 

Antenna 
Connector

 

Snap-in MMCX antenna connector.

 

Module status 
LEDs

 

Indicates communication with the CDMA network, report errors, 
and signal strength.

 

Serial number

 

A 15-digit number. Only the last 10 digits (after the dash “-“) are 
used for account activation.

 

 

Figure 2 

on page 2 shows the CDMA status LEDs and 

Table 3 

on page 2 

describes the LED functions. See 

Module Status LEDs

 

on page 4 for 

more information. 
 

PWR LED 

BUS LED 

AUTO LED 

Unused LED 

 

 

Gateway 

Status LEDs 

Wiring 

Terminals 

Serial number label

    

 

Antenna Connector  

Orange Z-Wave 
Antenna 
Module Status 
LEDs 