background image

MODEL 1100-I HEARTH CLASSIC PELLET INSERT

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

CONGRATULATIONS—You are now the proud owner of one of the finest inserts in the world for your home—the QUADRA-
FIRE!  
Now before installing your insert and building your first fire, record the serial number on the warranty card.  The serial
number is located on the safety label on the back wall of the hopper.

PLEASE READ ALL OF THE OWNER’S MANUAL AND SAFETY NOTES

IMPORTANT SAFETY NOTES

1.

When installing your insert, particular attention should be paid to fire protection. If this unit is not properly installed, a house fire may

result. For your safety, follow the installation instructions, and contact local building or fire officials about restrictions and installation
inspection required in your area.

2.

Read power supply section of component information (page 9) before you plug in the insert.

3.

Always unplug the insert before cleaning or servicing.

4.

Do not connect the insert to a chimney flue already serving another appliance.

5.

Do not connect this heater to any air distribution duct or system.

6.

The insert operates with a negative pressure firebox and a positive pressure exhaust. It is imperative that the chimney system be airtight

and installed correctly.

7.

Dispose of all ashes in a metal container.

8.

Do not burn garbage or flammable fluids such as gasoline, naphtha or engine oil.

9.

Do not use chemicals or fluids such as gasoline, lantern fuel, kerosene, or charcoal lighter fluid to start or freshen up a fire in this insert.

10. HOT WHILE IN OPERATION. Keep children, clothing, flammable liquids and furniture away from heater. Contact may cause skin

burns.

11. Comply with all minimum clearances to combustibles as shown on page 5.
12. The Quadra-Fire 1100-I is tested and approved for pelleted biomass fuel only. Burning of any other type of fuel voids your warranty!
13. Aladdin Hearth Products, manufacturer of the 1100-I pellet insert, reserves the right to alter its products, their specifications and/or price

without notice.
ALADDIN HEARTH PRODUCTS, GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE INSTALLATION OR
MAINTENANCE OF THIS UNIT AND ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

North 

America’s 

Best

401 N. Wynne Street
Colville, WA  99114

www.hearth.com/quad
[email protected]

SAVE THESE INSTRUCTIONS

(Revised 3/98)

Содержание Quadra-Fire 1100-I

Страница 1: ...ribution duct or system 6 The insert operates with a negative pressure firebox and a positive pressure exhaust It is imperative that the chimney system be airtight and installed correctly 7 Dispose of...

Страница 2: ...NOTES Page 2...

Страница 3: ...de air 7 Direct connect without outside air 7 Installed as a built in outside air optional 7 Floor protection 8 Chimney and exhaust connections 8 Mobile home installation 8 Vent termination requiremen...

Страница 4: ...SAFETY LABEL FOUND ON INSIDE OF RIGHT FACE SIDE OF INSERT Page 4...

Страница 5: ...Page 5...

Страница 6: ...Insert top to mantel 9 230mm C Insert top to face trim 0 0mm D Insert side to face trim 0 0mm E Floor protection hearth extension 6 150mm F Floor protection to the side of door 8 200mm MINIMUM CLEARAN...

Страница 7: ...Page 7...

Страница 8: ...r walls and ceiling roof must be maintained 6 This insert is to be grounded with 8 copper grounding wire or equivalent terminated at each end with an N E C approved grounding device 7 Refer to clearan...

Страница 9: ...he amperage draw on this insert is 05 amps so generally the lowest anticipator setting will work 2 When mounting the thermostat on a wall be sure to follow your thermostat installation instructions ca...

Страница 10: ...g chart can be used to determine whether to use 3 or 4 76mm or 100mm diameter pipe The table below can help you determine the equivalent feet of pipe used for venting when installing a pellet applianc...

Страница 11: ...the fuel feed by pulling the rod back to increase the feed and sliding it forward to decrease the feed 5 Tighten the set screw and the wing nut NOTE Adjust fuel after the convection blower has been op...

Страница 12: ...thermostat is not calling for heat the combustion blower will stay on for approximately 10 minutes This is normal b Next adjust the thermostat to its highest setting The red light next to the reset bu...

Страница 13: ...einstall the bottom cover plate by sliding it back into place and turning the two screws in a clockwise direction until tight Close bottom access door Reinstall the stainless steel cover inside the fi...

Страница 14: ...edges of the glass Be sure glass is centered in the opening i e same space top and bottom left and right 6 Reinstall screws and glass tabs tightly enough to hold everything in place 7 Check again for...

Страница 15: ...operly B The green light located on the top of the control box notifies you that the insert has reached a temperature of 200 F 93 C in the firepot If this light is not lit in the first four minutes of...

Страница 16: ...are having fuel problems check the following A Check the ramp in the firepot to see that it is free of fuel or other materials B Check the set screw on the end of the motor shaft to see that it is tig...

Страница 17: ...If it does not turn on check the following 1 Check the connections under the firepot Ceramic wire nuts must be used to withstand the heat produced by the firepot 2 Make sure that the igniter is prope...

Страница 18: ...nap disc cools and resets itself 13 LARGE FIRE ASH BUILDUP AND DIRTY GLASS A Clean the firepot Check the firepot gasket for a good seal between the firepot and firebox surface B Visually check the cle...

Страница 19: ...NOTES Page 19...

Страница 20: ...addin s one year warranty program Aladdin Hearth Products will not be responsible for any alteration to the unit which causes sooting that results in damage to the interior or exterior of the building...

Отзывы: