AK4000 Ethernet Product Family  

Document 180-0008-001 R08 

 
 
 
 

   

Part #                    Description                                    

CLEI Code   

 Kit Part #                  Description 

                  

AK400C  CO Ethernet line card, 50 Mbps at CSA, Line powering 

VAUIAG8J 

AK4000C  CO Ethernet Kit (AK400C & AK100S)  

AK401C  CO Ethernet line card, 50 Mbps at CSA 

VAUIAG9J 

AK4001C  CO Ethernet Kit (AK401C & AK100S) 

AK400R  RT Ethernet line card, 50 Mbps at CSA 

VAUIAHAJ  

AK4000R  RT Ethernet Kit (AK400R & AK100S) 

AK410C  CO Ethernet line card, 25 Mbps at CSA, 45 Mbps max, Line powering VAUIACWJ 

AK4010C CO 

Ethernet Kit (AK410C & AK100S) 

AK411C  CO Ethernet line card, 25 Mbps at CSA, 45 Mbps max 

VAUIACXJ AK4011C 

CO 

Ethernet Kit (AK411C & AK100S) 

AK410R  RT Ethernet line card, 25 Mbps at CSA, 45 Mbps max 

VAUIACYJ AK4010R 

RT 

Ethernet Kit (AK410R & AK100S) 

AK420C  CO Ethernet line card, 10 Mbps at CSA, 20 Mbps max, Line powering VAUIAFZJ 

 

AK4020C CO 

Ethernet Kit (AK420C & AK100S) 

AK421C  CO Ethernet line card, 10 Mbps at CSA, 20 Mbps max 

VAUIAF0J  

AK4021C  CO Ethernet Kit (AK421C & AK100S) 

AK420R  RT Ethernet line card, 10 Mbps at CSA, 20 Mbps max 

VAUIAF1J  

AK4020R  RT Ethernet Kit (AK420R & AK100S) 

AK100S  1RU Shelf (w/ AK100F fan module)  

VAMB410F  

 

   

 

The AK4000 Ethernet product family enables point to point transport of Ethernet services over bonded pairs of copper, optimized 
for CSA distances (9kft 26AWG or 12kft 24AWG).  The AK4000 family consists of Ethernet Central Office and Remote cards 
that plug into a 1RU high housing for 19” and 23” racks and for wall mounting.  The remote card is either line powered by the 
Central Office card or locally powered.  Aktino products utilize a technology “MIMO on DMT” which uses coordinated signal 
processing over multiple transceivers to achieve significant performance improvements over standard DSL technology.  Refer to 
the AK4000 Ethernet Technical Practice (180-0007-001) for more comprehensive information and troubleshooting. 

 

Installation is identical for both the CO and RT ends. 

#1 Mounting 

(see Figure 1) 

 

The AK4000 Family’s shelf (AK100S) can be mounted in 
either 19 inch or 23 inch racks.  The AK100S chassis 
includes flanges for both 19 and 23 inch mounting.  Screws 
for mounting to both the chassis and the rack are included.  
Mounting holes are provided for flush or mid mount.  The 
unit can also be mounted on a wall using either 19 or 23 inch 
flanges.  An optional hinged bracket (AK100B) is available 
for easier wall mounted access. 

 
 
 
 
 
 
 
 
 
 

#2 Connections 

Frame Ground Connection (see Figure 2)

The Ground Lug located on the right hand side of the back 
panel can accommodate up to 6 AWG wire.  Use a wire 
gauge for grounding at least as heavy as the power wiring.  
Attach the grounding wire to the AK100S Ground Lug to a 
nearby grounding screw on the equipment rack or facility 
ground.  

Note that the ground connection is required for 

proper system operation.

 

Power Connection 

(see Figure 2)

 

A 7.5A to 10A UL listed fuse/circuit breaker must be 
installed ahead of this unit. 
To access the power block, the Protective Cap located on the 
left hand side of the back panel must be removed.  Unscrew 
the captive screw on the right side of the Protective Cap, 
slide the cap to the left and lift off.  Labels of the power 
block and wirewrap connections are silk screened on the 
Protective Cap as well as the back panel. 
Two redundant power buses are provided (A and B).  The 
two power inputs are identical and can be used for redundant 
power configurations.  Insert the ends of the -48 Vdc and 
Return power wires (16 AWG wire is recommended) into 

the A and B holes on the left side of the power block.  Route 
the power wires towards the left of the back panel so that the 
Protective Cap can be reinstalled. 

Alarm Connections 

(see Figure 2)

 

The alarm wirewrap connections are located under the 
Protective Cap.  Unscrew the captive screw on the right side 
of the Protective Cap, slide the cap to the left and lift off.  
Labels of the wirewrap connections are silk screened on the 
Protective Cap as well as the back panel.  Each alarm 
consists of a three pin wire wrap header.  These are generally 
only used on the CO end. 

Ethernet Data Connections 

(Figure 3)

 

Attach Ethernet data cables to any of the four 10/100BaseT 
RJ45 plugs on the front panel.

 

Caution

   To order to comply with the intrabuilding 

lightning surge requirements, intrabuilding Ethernet wiring 
must be shielded, and the shield for the wiring must be 
grounded at both ends. 
 

AK4000 Ethernet System Quick Installation

 

                 1-888-AKTINO9

Figure 1 Mounting 