    SOUND LEVEL METER  

User’s Manual

                     

ATE-9051

www.tmatlantic.com

Содержание ATE-9051

Страница 1: ...SOUND LEVEL METER User s Manual ATE 9051 www tmatlantic com...

Страница 2: ...nvironment conditions Altitude lower than 2000 meters Relatively humidity 90 RH Operation Ambient 0 40 Maintenance Clearing Repair or servicing not covered in this manual should be performed by qualif...

Страница 3: ...raffic access and household etc This unit confirms to the IEC61672 1 CLASS2 for Sound Level Meters MAX MIN measurements Over range display Under range display A C Weighting FAST SLOW response Analog A...

Страница 4: ...4 digits LCD display with a resolution of 0 1dB Display Update 2 times sec MAX hold Hold the Maximum reading MIN hold Hold the Minimum reading HOLD Hold the readings Alarm function OVER is when input...

Страница 5: ...EDA1604 or IEC 6F22 Power life About 30hours Operation temperature and humidity 0 40 10 RH 90 RH Storage temperature and temperature 10 60 10 RH 75 RH Dimension 278 L x 76 W x 50 H mm Weight 350g Acce...

Страница 6: ...REC FAST A C 1 2 3 4 5 8 6 7 10 9 11 DC 9V OUTPUT CAL 18 12 13 14 15 16 17 Windscreen LCD 6...

Страница 7: ...CTION LCD 4 digits MAX Maximum hold MIN Minimum hold OVER over range UNDER under range FAST Fast response SLOW Slow response dBA A Weighting responseto human sense dBC C Weighting response to machine...

Страница 8: ...power off Low battery indicate REC button 3 0 DATALOGGER function Press REC button after it power on the display will show REC to start Data Recording press the button again to delet the record Note...

Страница 9: ...under time adjustment mode at the time the display will show the date as following Press the SETUP button second time the display showing The display showing minute adjustment mode press LEVEL to mak...

Страница 10: ...the adjustment press HOLD to keep the setup Press the SETUP button fourth time the display showing The display showing date adjustment mode press LEVEL to make the adjustment press HOLD to keep the se...

Страница 11: ...ess HOLD to keep the setup Press the SETUP button sixth time the display showing The display showing year adjustment mode press LEVEL to make the adjustment press HOLD to keep the setup Press the SETU...

Страница 12: ...display showing initialization of the time chip time and date have returned to factory setup When the battery is exhausted or replaced if the time can t be adjusted then please initialize the time chi...

Страница 13: ...1 time per second MAX MIN button Maximum and Minimum hold Press this button for one time to enter MAX MIN measurement MAX will appear on LCD maximum sound level will be captured and held until higher...

Страница 14: ...nd Auto level in the circular Backlight button Turn the backlight on off Frequency weighting select button A A Weighting C C Weighting HOLD button Press HOLD button The hold function freezes the readi...

Страница 15: ...r 1 35mm USB interface USB signal output is a 9600 bps serial interface AC DC signal output earphone outlet OUTPUT GROUND OUTPUT AC DC AC Output voltage 1Vrms corresponding to each range step Output i...

Страница 16: ...RES Make the following switch settings Frequency weighting A weighting Time weighting FAST Level range 50 100dB Insert the microphone housing carefully into the 1 2 inch insertion hole of the calibrat...

Страница 17: ...ON Remove the battery cover on the back and put in one 9V battery Recover the back cover When battery voltage drops below the operating voltage or battery aging this symbol will appear on LCD Replace...

Страница 18: ...for measuring maximum and minimum noise level Hold the instrument comfortable in hand or fix on tripod and measure sound level at a distance of 1 1 5 meter 8 NOTICE i Do not store or operate the instr...

Страница 19: ...D USB interface cable screwdriver tripod windscreen DC 9V power supply 10 Installing the software 1 0 Start windows 1 1 Insert the CD into the CD drive 1 2 Run SETUP EXE installation program in file D...

Страница 20: ...to the instruction 3 After Driver installation a new COM port will be added to the Ports in the Device Manager Port number will be ranged following the primary COM ports such as COM3 or COM4 4 Entry...

Страница 21: ...menu REAL TIME SETUP to set the monitoring data data volume response monitoring time 1 6 DATALOGGER menu The computer read the memory data in the meter when REC not appear on the display and the conn...