AKO AKO-D14423-P Скачать руководство пользователя страница 1

3

5

D

1

4

4

2

3

P2 R
EV

.0

2 2
0

1

6

AK

O E

LE

CTR

OM

EC

ÀN

IC

A, S

.A

.L.

We 

re

se

rve 

th

e ri

gh

t to 

su

pp

ly 

ma

te

ria

ls 

wh

ich 

ma

y b

e s

lig

htly 

diff

ere

nt 

fro

m t

ho

se 

de

scr

ib

ed 

in 

ou

r D

ata 

Sh

ee

ts. 

Up

da

te

in

fo

rm

atio

n  on 

ou

r  w

eb 

site

 

Av. 

Roq

uet

es, 

30-

38

088

12 

San

t P

ere 

de 

Rib

es

Bar

cel

ona 

(E

spa

ña)

www.ako.com

[email protected]

T el

. (3

4) 

93

8 1

42 

70

0

Fa

x (3

4) 

93

8 9

34 

05

4

1- Warnings

-Using the equipment without following the manufacturer's instructions may affect the device's safety requirements. To ensure that 

the device operates correctly, only probes supplied by AKO should be used. 

-The unit must be installed in a location protected from vibrations, water and corrosive gases, where the ambient temperature does not 

exceed that shown in the technical data.

-To ensure a correct reading, the probe must be situated in a location without any external heat influences except for the temperature 

which is being measured or controlled.

-The power supply circuit must be provided with a main switch rated at at least 2 A, 230 V, located close to the equipment. The cables 

will enter through the back and should be type H05VV-F or H05V-K. 

2

-The gauge will depend on local regulations, but should in no case be less than 1 mm .

2

-Connecting wires for the relay contacts should be sized 2.5 mm .
-Between -40 ºC and +20 ºC, if the probe NTC is prolonged till 1.000 m with a mínimum of cable 0,5 mm², the maximum deviation will 

be of 0,25 ºC (extension cable for probe ref. 

AKO-15586

)

NOTE: 

Equipment not compatible with 

AKO-14917 

(external communication module) and 

AKO-14918 

(programming key)

2- Wiring

The probe and its cable should 

NEVER 

be installed in the same conduit as power, control or supply cables.

Installation instructions

GB

D144H23P2 Ed.03

ECO relay 

ON

COOL relay ON (P0=0)

Standby

mode

Keyboard

Fast Freezing 

mode

AUX relay ON

RES relay ON (P0=1)

Lights ON (P6=3)

DEF relay ON

Program Mode

FAN relay ON

Display

SET

ESC

3- Installation

71mm

29mm

DEFAULT SETTINGS BY APPLICATION (InI)

2

-18

10

0

3

12

8

0

30

8

8

30

20

20

20

20

20

1
0

0
0

1
0

1
0

1
0

4

4

4

4

24

SP

d1

F3
P0

d0

F0

4

6

5

3

2

1

20

1
0

24

21

7

99

0

0
0

96

M

ul

tip

ur

po

se

User Manual available at

www.ak

o.com

AKO-D14423-P
AKO-D14423-P-RC

AUX Relay

Function as per parameter P6

S1:

 Probe 1, temperature in the chamber or cabinet

S2/DI2:

 Probe 2, defrost or digital input 2 
(as per P4)

S3/DI1:

 Probe 3, temperature of product / 2nd 

defrost, or digital input 1 (as per P4)

AUX.

I max.:

16 A

A

A

1

A

A

S1

S2 or DI2

S3 or DI1

1

2

3

4

AKO-D14423-P / D14423-P-RC

90-240 V~ 

50/60 Hz

COOL

FAN

AUX

AUX.

Modbus*

L N

5

6

7

8

9

10 11 12

16

15

14

13

DEF

Tr+

Gnd

Tr

-

Access to set point and programming

 

Operation

ESC

 key / 

%

Press for 5 seconds to start/stop Fast Freezing mode (rapid 
cooling).
In  the  programming  menu,  exit  without  saving  parameter, 
return to previous level or exit programming.

SET

 key

Press for 5 seconds to modify the set point (SP) (Set Point).
Press for 10 seconds to go to the programming menu.
In the programming menu, go to the level displayed or accept 
the new value while setting a parameter.

Up key 

N

 / 

H

Pressing for 5 seconds starts/stops defrosting.
The  programming  menu,  allows  you  to  scroll  through  the 
various levels or, during the setting of a parameter, to change 
the value.

Down key 

Q

 / 

m

Pressing for 5 seconds activates Standby mode, pressing for 2 
seconds returns the equipment to normal mode. In Standby 
mode,  the  equipment  performs  no  actions  and  only  the 
indicator is displayed on the screen 

m

.

The  programming  menu,  allows  you  to  scroll  through  the 
various levels or, during the setting of a parameter, to change 
the value.

5- Start-up

On power-up, the equipment will start up in Wizard mode 
(P3 / 1 flashing), press

 

 

N

 or 

Q

 to select the most 

appropriate application and press 

SET

.

1

: Multipurpose

2

: Frozen

3

: Fruits and vegetables

4

: Fresh fish

5

: Soft Drinks

6

: Bottle racks

7

: AC

The wizard will configure the parameters of the equipment for 
the  chosen  application  (see  table  "Default  settings  by 
application").

4- 

* According to model

WARNING:

  The  default  parameters  by  type  of 

application  have  been  defined  for  the  most 
common  applications.  Check  that  these 
parameters are suitable for your installation.

Fr

oz

en

Fr

ui

ts 

an

d

ve

ge

ta

bl

es

Fr

es

fis

h

So

ft 

dr

in

ks

Bo

tt

le 

ra

ck

s

A

C

5 sec.

Temperature

Indication

Release 

SET

to access the

set point

Release 

SET

to access

programming

10 sec.

t

SET

Temperature

Indication

Current

Value

New

Value

Change

value

Accept value

and exit

SET

Change set point (SP)

Level 1

Menus

Level 2

Parameters

Level 3

Values

OK

OK

OK

Change

menu

Return to

Level 1

Back up one level without saving changes

Exit Programming

Change

param.

Change value

SET

ESC

ESC

ESC

Programming Menu (parameters)

SET

SET