OPERATING MANUAL
9 (112)
Document-ID: 947422-000 Multi
Version: C0
EN
8.1 Mounting Steps
Step 1
Select a location that is within the environmental limitations of the receiver and where it is
difficult for unauthorized persons to obtain access to the receiver. Mount the receiver with the
cable glands facing downwards.
If possible mount the receiver inside a control cabinet. Note that this is only possible if the cabi-
net is made out of plastic or materials that not have a negative effect on radio emissions.
Step 2
Drill 4 holes (for measures see fig. 11). Mount the receiver.
Step 3
Connect wiring for output signals and power supply. Use cable ties to secure the wires and
ensure that the wiring will not be affected by abrasion, heat and/or exhausts.
Connect 12-24 V DC (+) to position 3 and ground (-) to position 2
(see
3
and
2
in fig 1).
Connect the equipment to be controlled to output terminals 1...6
(see
11
in fig. 1)
and equipment ground to position 2 (see
2
in fig. 1). If the outputs are to be
pow ered by the same 12-24 V DC supply as the receiver place a jumper between the Output
Power Input (SW) and Positive (+) 12-24 V DC using a 0,75 mm
2
cable (see fig. 3).
PB
-F
re
e
PB-Free
P0
YWW
941551
}
}
Figure 3.
Configuring internal supply of output power