Akai AUS-12H53R130D2 Скачать руководство пользователя страница 1

N13275

3.50kW INVERTER 

Reverse Cycle Split 

System Air Conditioner

AUS-12H53R150P9(De3)
Instruction Manual

AFTER SALES SUPPORT 

NZ: 0800 836 761

AU: 1300 886 649 

PROTECT YOUR WARRANTY

This unit must be installed by a registered, licensed installer as required 

by Government regulations.

FOR THE INSTALLER

Содержание AUS-12H53R130D2

Страница 1: ...m Air Conditioner AUS 12H53R150P9 De3 Instruction Manual AFTER SALES SUPPORT NZ 0800 836 761 AU 1300 886 649 PROTECT YOUR WARRANTY This unit must be installed by a registered licensed installer as required by Government regulations FOR THE INSTALLER ...

Страница 2: ......

Страница 3: ... unit 7 Installation of the Indoor unit Securing the mounting plate on the wall 8 Drilling the wall 9 Wiring 10 Attaching the indoor unit to the mounting plate 11 Pipe connection Arrangement of the drain hose 12 Wall sealing and Pipe fastening 13 Installation of the Outdoor Unit Wiring 15 Connection diagram 16 Installation of the drain joint 17 Join the connecting pipe Air exhausting 18 Process of...

Страница 4: ...an Insert the power plug correctly and firmly into the socket thereby avoiding the risk of electric shock or fire due to insufficient contact Check that the socket is suitable for the plug otherwise have the socket changed Do not install the appliance at a distance of less than 50cm from inflammable substances alcohol etc Or from pressurised containers e g spray cans If the appliance is used in ar...

Страница 5: ...ir could be dangerous for your health Particular care should be taken in the rooms where there are children old or sick people If the appliance gives off smoke or there is a smell of burning immediately cut off the power supply and contact the Service Centre Have repairs carried out only by an authorised Service Centre of the manufacturer Incorrect repair could expose the user to the risk of elect...

Страница 6: ...ner as instructed in this booklet These instructions are not intended to cover every possible condition and situation As with any electrical household appliance common sense and caution are therefore always recommended for installation operation and maintenance Ensure that the appliance is disconnected from the power supply when it will remain inoperative for a long period and before carrying out ...

Страница 7: ...ed physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Do not climb onto or place any heavy or hot objects on top of the appliance Do not leave windows or doors open for long when the air conditioner is operating Do not direct the airflow onto plan...

Страница 8: ...r this air conditioner has qualifications and experience in refrigerant products NOTE Installation location notes are found on pg 7 NOTE The figures of the air conditioner and its working parts above and right are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased Please always refer the actual product purchased whil...

Страница 9: ...h of the connecting pipe is 10m The allowable distance between the indoor unit and outdoor unit is 5m Cover connecting pipe with adiabatic material Sponge plastic adiabatic material with the thickness of 8mm Confirm the installation position by the mark of the indoor mounting plate NOTE Do not raise the drain hose The connecting pipe can be led from the back right underside or back left side front...

Страница 10: ...en pass Select a place where the air discharge and the operating sound level will not disturb neighbours Avoid installing the unit where it will be exposed to direct sunlight other wise use protection if necessary that will not interfere with the air flow Leave the spaces as shown in the picture for the air to circulate freely Install the outdoor unit in a safe and solid place If the outdoor unit ...

Страница 11: ...oid the mounting plate shaking or moving When the expansion bolts are used two holes 11x20 or 11x26 should have the distance of 450mm between them adopted Mark the wall to confirm the position of holes and drill holes on the wall Center of hole 65mm Center of hole 65mm Pipe hole ...

Страница 12: ... the plug is accessible For some models whose cooling capacity are above 4600W 17000BTU h an all pole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule 4 Installation of the drain hose The drain hose must be arranged beneath the connecti...

Страница 13: ...comes out of the left side of the indoor unit the drain hose must be refitted otherwise water leakage may occur Readjustment methods Interchange the position of drain hose and drain rubber plug Clearance is not allowed after refit it would lead to water leakage 5 Attaching the Indoor unit to the mounting plate Let the pipe go through the hole you have made in the wall and attach the indoor unit to...

Страница 14: ...he centre of joint in line with that of flare and tighten the nut of connecting pipe with wrench Fig 2 IMPORTANT Do not exhaust the inside air just by loosing the nut as there is a certain amount of pressure inside the tube of the indoor unit Please do not apply extra effort for fear of damaging the expansion orifice 7 Arrangement of the drain hose To drain the condensate water easily the drain ho...

Страница 15: ...12 8 Wall sealing and Pipe fastening Use putty to seal the wall hole Use a clamp pipe fastener to secure the pipe at specified position ...

Страница 16: ... the fixing clip to loosen the fixing clip 3 Loosen the fixing screw of the wire terminal board pass the power wire and signal wire through the fixing clip Then firmly fix the power wire and signal wire on the terminal board with the fixing screw Earth wire must be connected firmly Single Split Model Dual Split Model Connecting cable Outdoor unit terminal Connecting cable Outdoor unit terminal Con...

Страница 17: ...cting hole Please utilize outdoor pipe support when the cable wire is led from the backside 4 Tighten the self tapping screw on the fixing clip 5 Install the maintenance board After the pipes and cable wire are installed please seal the sponge block as per drawing indication ...

Страница 18: ...able for reference IMPORTANT Please take the electric circuit diagram attached to the indoor outdoor units as major reference while installing The power wire and signal wire between the indoor outdoor units must be connected one by one as per corresponding number on the wiring terminal board The connecting cables must be clipped together L 2 N L 2A 2B N Connecting cable Indoor unit A terminal L 2 ...

Страница 19: ...Please keep the interconnection cable away from the connecting tube All the models shall be connected with the mains which have system impedance limitations While installing the unit please see the following table for impedance information or consult with your supply authority The following information and specifications are subject to change without prior notice due to continuing research 2 Insta...

Страница 20: ...seconds Use soapy water to check the gas leakage especially at all joints If there is no gas leakage please turn the valve cork of the liquid side at 90 counter clockwise again Press the cork of service port at the gas shut off valve 10 seconds later when you see a foggy gas discharged that means inner air has exhausted out Use an Allen key to turn the valve cork of both the liquid shut off valve ...

Страница 21: ...the pipe cutter to cut off the broken part of flare Remove burrs at the cut of the flare Insert a nut into the connecting pipe and do flaring with specified flaring tools reamers for example Check the quality of the flaring technique ...

Страница 22: ... mentioned method Screw the gas shut off valve to close connect charging hose low pressure to the service valve and then open gas shut off valve again Connect the refrigerant bottle to the charging hose and then convert it Fill in liquid refrigerant as the above table Disconnect the manifold gauge after turning off the shut off valve and then open gas shut off valve again Tighten nuts and caps of ...

Страница 23: ... of remote controller After that press every button to test their functions Check switch operation Open the front grille and press the check button Switch on the power source and then the operation test is activated If the indicator lamps light up at first and then go out in succession or the LED window of the indoor unit illuminates at first and then goes out the system is under normal operation ...

Страница 24: ...s and completely reliable We are so confident in our products we back them up with a full 2 year replacement warranty Now you too can relax knowing that you are covered Customer Helpline NZ 0800 836 761 AU 1300 886 649 This Product is covered by 2 year replacement warranty when accompanied by proof of purchase ...