12AVD

 

Always read before installation.

„

  

Applicable models

AX

H

P

36AVD

AX

HP71AVD

AX

HP112AVD

„

  

Important reminder

- THOROUGHLY READ THESE INSTRUCTIONS BEFORE STARTING THE INSTALLATION AND FOLLOW 

ALL PROCEDURES DESCRIBED WITHIN.

- KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

After installation, always use the checklist to perform a final inspection.

                         OPERATION

 

MANUAL

[ Model ] 

Ceiling Suspended 

Type

Aisin 

INDOOR UNITS

Содержание AXCP112AVD

Страница 1: ...inder THOROUGHLY READ THESE INSTRUCTIONS BEFORE STARTING THE INSTALLATION AND FOLLOW ALL PROCEDURES DESCRIBED WITHIN KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE After installation always use the checklist to perform a final inspection OPERATION MANUAL Model Ceiling Suspended Type Aisin INDOOR UNITS ...

Страница 2: ...AXHP112AVD AXDP22P7D AXDP28P7D Brand AISIN SEIKI CO LTD Marca Serial number See the number on the unit label N di serie vedere il numero sulla targa dati Year of production See the year on the unit label Anno di produzione vedere il numero sulla targa dati Comply with following Directives of the council of the European Community E conforme alle seguenti Direttive della Comunità Europea 1 Directive...

Страница 3: ...suring safety WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices After reading keep this manual in a convenient place so that you can refer to it whenever necessary If the ...

Страница 4: ...ake proper measures so that the amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched so that they do not play with the indoor unit or its remote controller Accidental operation by a child may result in injury or elec tric shocks Do not allow a child to mou...

Страница 5: ...not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it occurs stop the air conditioner and call your local dealer for assistance NOTE TO SERVICE PERSONNEL WARNING RISK OF ELECTRIC SHOCKS OR A FIRE When checking the electric components such as the inside of the control box fan motor drain pump etc make sure to s...

Страница 6: ...ccording to the set temperature on the remote controller Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units The unit is individually operated NOTE Contact your local dealer in case of changing the combination or setting of group control and two remote controller control systems Please do not change the comb...

Страница 7: ...y yourself Make sure that a separate power supply circuit is provided for this air conditioner and that all electrical work is carried out by qualifed per sonnel according to local laws and regulations Pay attention to running noises too Are the following places selected a A place that can sufficiently withstand the mass of the air conditioner with less running noises and vibrations b A place wher...

Страница 8: ...kes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIMER OPERATION Perform the following operation to prevent heat ing capacity decrease and discharge of cool air AT THE START OF OPERATION AND AFTER THE DEFROST OPERATION A warm air circulating system is employed an...

Страница 9: ...oor temperature and then use the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically set direc tion for a period of time to prevent condensation on the horizontal blade The remote controller dis plays the airflow direction that is set If the PROGRAM DRY OPERA...

Страница 10: ...rflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is moving may get your fingers pinched The four fins for the left and right airflow direction operate in the same direction as a unit Do not operate adjacent units in the state s...

Страница 11: ...ectric shocks or a fre Never put your fngers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air conditioner with water It may cause electric shocks or a fre due to leak age Make sure to turn off the air conditioner when taking care of the air conditioner and discon nect ...

Страница 12: ...ning 4 Attach the air flter After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 and securely fix the grille 6 Turn off the indication or Time to clean flter displayed on the remote controller after turning on the power The indication can be turned off whe...

Страница 13: ... stain cannot be wiped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner polishing powder and liquid insecticide sold in the market It may cause discoloration and deformation Do not wash the flter with warm water of 50 C or higher It may cause discolorati...

Страница 14: ... the power circuit breaker is turned on some watts of electricity is being used even if the air conditioner is not operating Turn off the power circuit breaker for saving energy The display on the remote controller will vanish when the power circuit breaker is turned off Clean the air flter and outside panel Be sure to replace the air filter to its original place after cleaning Refer to 8 MAINTENA...

Страница 15: ......

Страница 16: ...04 2014 ...

Отзывы: