ASSEMBLY AND CONNECTION EVALUATION
Check the following aspects:
-
The state of the LEDs of the main control board
and the rest of control elements. Check the self-
diagnose section of the data sheet of the
elements.
-
All thermostats are powered.
Important:
In the Main Control Board, to verify the
correct performance, check D3, D11 and D19 LEDs.
SUBORDINATE ZONES SETTINGS
IMPORTANT:
Can only be configured as second zones the zones controlled by a
wired zone module.
To configuration secondary zones, follow these instructions:
-
Perform the setup according to the next section.
-
Disconnect the thermostat from the subordinate module. After a few seconds, this module will be available on the
menu of associated outputs.
-
Once all the subordinate module, configure the module or modules main and associate the sub modules that you
want to each one of them.
Note:
It is recommended the use of a Blueface thermostat for configuring subordinated zones.
INITIAL SETUP
Important:
Before performing the initial set up of the system, configure firstly the subordinated zones, see
section.
AIRZONE THERMOSTATS BLUEFACE AND THINK
Important:
Once you start the process, it cannot be interrupted. You will be able to modify the desired
parameters later.
Language/Country
Select your language and country. These are the available languages: Spanish, English, French, Italian, German and Portuguese.
Meaning
D3
Main control board
activity
Blinking
Green
D11
Main control board
power
Solid
Red
D19
Association channel:
active
Solid
Red