background image

 1

 

ICE A/C & HEX Combo Unit I&O Manual 07/2020 Rev.1

Part Number 03816

Industrial Climate Engineering

®

 Division of AIRXCEL

®

, Inc.

P.O. Box 5104 • Cordele, Georgia 31010

2002 Hoover St. • Cordele, Georgia 31015

(229) 273-9558 • Fax (229) 273-5154

E-mail: [email protected] • Internet: www.acice.com

Models HC2010 & HC3012

Installation & Operation Manual

Cabinet Climate Control Combo Unit 

Air Conditioner with Heat Exchanger

The most current version of this manual can

be found at www.acice.com.

Содержание ICE HC2010

Страница 1: ...4 Cordele Georgia 31010 2002 Hoover St Cordele Georgia 31015 229 273 9558 Fax 229 273 5154 E mail icesales airxcel com Internet www acice com Models HC2010 HC3012 Installation Operation Manual Cabinet...

Страница 2: ...ipment 2 TRANSPORT the UNIT UPRIGHT Laying it down on its side may cause the fan to shift in its mounting or damage to other components 3 TURN ELECTRICAL POWER OFF AT THE breaker or fuse box BEFORE in...

Страница 3: ...transmitter panel END USER Retain these instructions for future reference Table of Contents Chapter 1 Description Specifications 1 1 Foreword 4 1 2 General Description 4 1 3 Features 5 1 4 Standards...

Страница 4: ...lower than the cabinet inner temperature the heat pipe exchanger reduces heat dissipating consumption The operating principle of Air Conditioner with Heat Exchanger is shown as Figure 1 The heat excha...

Страница 5: ...for the application of electric and electronic product Storage IEC 60721 3 2 Environmental conditions for the application of electric and electronic product Storage Transportation IEC 60721 3 3 Envir...

Страница 6: ...lation 2 3 Installation of the Combo Unit The following tools are required for installation 1 Specialty screwdriver for removing external anti theft screws 2 Phillips screwdriver for removing the cont...

Страница 7: ...ause serious injury death and or property damage Installation or repairs made by unqualified persons could result in hazards to you and others Installation MUST conform with local codes or in the abse...

Страница 8: ...ed 6 Alarm output is securely connected 7 The input voltage is within the acceptable range 8 Fan runs freely with no abnormal noise 9 Check the input AC voltage and DC voltage with current meter to se...

Страница 9: ...ernal fan are started entering the heat exchanger mode Air Conditioner running When the cabinet internal temperature rise continuously to 104 F 40 C the compressor will be started If the external ambi...

Страница 10: ...pload protocol VAC Under 187 192 V Detected AC voltage is too low Stop compressor and upload protocol VDC Over 59 57 V Detected DC voltage is too high Stop internal external fans and compressor and up...

Страница 11: ...Temp sensor Coil Temp value is be yond sensor checking range Upload protocol Comp Fault 5 5 C On cooling mode the difference between evaporator coil Temp and cabinet return Temp is less than 5K conti...

Страница 12: ...s used to confirm the entry ESC Quit button which is used to return to the previous page menu If there is no keyboard operation for a continuous 60 seconds it will automatically return to the normal d...

Страница 13: ...nd alarm output cables from the Combo Unit before any maintenance and do not reconnect them until the maintenance is completed After the Combo Unit is powered on please refer to section 2 9 and check...

Страница 14: ...if there is any abnormal noise 12 months Drainage Pipe Visually check if the drainage outlet is blocked 6 months Condenser Check the cleanness of the condenser and clean it with compressed air 6 month...

Страница 15: ...irement Check the detected internal Temp and the exter nal fan status through the display interface Fan has abnormal noise Bearing wear Replace fan Fan impeller in contact with other parts Check wheth...

Страница 16: ...date of manufacture and serial number on the barcode is showed as follows The first 13 bit M019019000800 is the manufacture definition The value of 14 18 bit 13701 stands for the date of manufacture J...

Страница 17: ...2 101 213 32 61 3913 32 1001 3 8 10 311 16 94 311 16 94 373 16 945 3713 32 950 221 32 68 13 32 28 231 32 76 311 2 800 161 16 408 1719 32 447 3823 32 984 217 16 545 183 32 460 5 1 8 130 7 7 8 200 7 7 8...

Страница 18: ...927 32 250 23 16 56 323 32 95 31 16 78 21 2 64 83 16 208 75 32 182 535 32 1350 20 27 32 530 52 11 32 1330 23 17 32 598 8 3 32 206 313 16 97 513 16 1300 535 32 1350 215 16 75 2 7 16 62 7 3 16 183 15 1...

Отзывы: