background image

Technical Supplement

Reporter

Содержание Aqua-Hot Reporter

Страница 1: ...Technical Supplement Reporter...

Страница 2: ...Fans 6 Heating 6 Diagnostic 6 Pin Out Information 6 Introduction 6 J8 6 J1 6 J7 7 J3 7 J9 7 J2 8 Manual Mode Reporter 2v9 9 System Schematics 10 400D 10 Power Inputs Pumps Safeties 10 Burner 11 Electr...

Страница 3: ...nctions Each of these functions will be explained in detail Basic Features The Home Screen is the rst screen shown on the Reporter Reporter 1 0 and Reporter 2 0 home screens do differ The most substan...

Страница 4: ...RVC network indicating to the Reporter that it is to continue normal operation Loss of 6 consecutive signals from the RVC network will trigger the Reporter to de activate the Aqua Hot This serves as a...

Страница 5: ...he minimum current rating is the minimum requirement for what will operate the Reporter Operating at this current rating will not provide suf cient power to any components dependent upon the Reporter...

Страница 6: ...FULL 7 Once the tank is partially full deactivate the external uid ll pump and close the drain valve DO NOT disconnect the uid pump 8 Navigate to the PUMPS page of the TESTING section Figure 9 Figure...

Страница 7: ...ill display a low voltage fault If the Reporter drops below 11 2V DC for more than 30 seconds a safety mechanism will activate shutting down the Aqua Hot Low Level Cut Off Aqua Hot units require a min...

Страница 8: ...pulation of the elements listed There are four screens maintained under this tab Inputs from Coach Outputs to Coach Inputs from Aqua Hot and Outputs to Aqua Hot Figure 12 Figure 13 Figure 14 Pin Out I...

Страница 9: ...ched 12V J3 J3 serves as the RVC connection to the coach side comfort system if applicable The RVC indicator light located on the back of the Reporter serves as a valuable diagnostic tool when the nee...

Страница 10: ...Pump 1 Output 12V DC Pump 1 Ground Zone 1 Boost Pump 400 Series Pump 2 Output 12V DC Pump 2 Ground Power On Signal Pump 3 Output 12V DC N A on 400P and 400D Pump 3 Ground N A on 400P and 400D Electric...

Страница 11: ...utton at any time while enabled will reset the timer and run for an additional 3 days All heating zones are linked together and can be run at 25 50 75 and 100 as shown below The burner and electric ca...

Страница 12: ...Fluid Expansion Bottle Aqua Hot Aqua Hot Reporter Install OEM Supplement p 10 400D...

Страница 13: ...Fluid Expansion Bottle Aqua Hot Aqua Hot Reporter Install OEM Supplement p 11 400D...

Страница 14: ...Installing Heat Exchangers Aqua Hot Aqua Hot Reporter Install OEM Supplement p 12 400D...

Страница 15: ...Locations and Clearances Aqua Hot Aqua Hot Reporter Install OEM Supplement p 13 400D...

Страница 16: ...Plumbing the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 14 400D...

Страница 17: ...Plumbing the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 15 400D...

Страница 18: ...Wiring Heat Exchangers Aqua Hot Aqua Hot Reporter Install OEM Supplement p 16 400P...

Страница 19: ...Domestic Water System Aqua Hot Aqua Hot Reporter Install OEM Supplement p 17 400P...

Страница 20: ...Mounting the Aqua Hot LCD Aqua Hot Aqua Hot Reporter Install OEM Supplement p 18 400P...

Страница 21: ...Mounting the Aqua Hot LCD Aqua Hot Aqua Hot Reporter Install OEM Supplement p 19 400P...

Страница 22: ...Mounting the Aqua Hot LCD Aqua Hot Aqua Hot Reporter Install OEM Supplement p 20 400P...

Страница 23: ...Con guring the Zones Aqua Hot Aqua Hot Reporter Install OEM Supplement p 21 400P...

Страница 24: ...House Power Sense Aqua Hot Aqua Hot Reporter Install OEM Supplement p 22 450D...

Страница 25: ...Providing DC Power Aqua Hot Aqua Hot Reporter Install OEM Supplement p 23 450D...

Страница 26: ...Providing AC Power Aqua Hot Aqua Hot Reporter Install OEM Supplement p 24 450D...

Страница 27: ...Filling the Aqua Hot Aqua Hot Aqua Hot Reporter Install OEM Supplement p 25 450D...

Страница 28: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 26 450D...

Страница 29: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 27 450D...

Страница 30: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 28 600D...

Страница 31: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 29 600D...

Страница 32: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 30 600D...

Страница 33: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 31 600D...

Страница 34: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 32 600D...

Страница 35: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 33 600D...

Страница 36: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 34 675D...

Страница 37: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 35 675D...

Страница 38: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 36 675D...

Страница 39: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 37 675D...

Страница 40: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 38 675D...

Страница 41: ...Purging the Heating Loop Aqua Hot Aqua Hot Reporter Install OEM Supplement p 39 675D...

Страница 42: ...ing Systems LLC 7501 Miller Drive Frederick CO 80504 Visit us online at www aquahot com Call us at 800 685 4298 or 303 651 5500 2019 Aqua Hot Heating Systems LLC Printed in the USA SERVICE OEM SUPPLEM...

Отзывы: