13-1
TROUBLESHOOTING
SM HAFRPM 1-A.3 GB
13. TROUBLESHOOTING
NO
SYMPTON
PROBABLE CAUSE
CORRECTIVE ACTION
1.
The stand-by
indicator (red led)
on the central
control display
panel doesn’t light
up.
There is no correct voltage
between the line and neutral
terminals on main P.C.B
-If the voltage is low repair power
supply.
-If there is no voltage repair general
wiring.
-If there is correct voltage replace
main or display P.C.B’S
2.
The operation
indicator (green
led) on the central
control display
panel does not light
up.
The remote control batteries are
discharged
-Replace batteries of the remote
control.
3.
The operation
indicator (green
led) does not light
up when starting
from unit.
Check main P.C.B and display
P.C.B
-Replace P.C.B if necessary.
4.
The indoor fan
does not function
correctly.
Check the voltage between
indoor fan terminals on the main
P.C.B
-If there is voltage replace capacitor
or motor.
5.
The outdoor fan
does not function
correctly.
Check the voltage between out
door fan terminals on the main
P.C.B
There is voltage between
outdoor fan terminals on the
outdoor unit.
There is no voltage between
outdoor fan terminals on the
outdoor unit.
-If there is no voltage replace main
P.C.B
-Replace capacitor or motor.
-Check and repair electrical wiring
between indoor and outdoor units.
6.
The compressor
does not start up.
Check voltage on compressor
terminals on the outdoor unit.
(with ammeter)
Check if there is correct voltage
between compressor terminals
on the outdoor unit.
-If no voltage replace main P.C.B
-If low voltage repair power supply.
-If the voltage correct replace
capacitor or compressor.
-If there is no voltage repair
electrical wiring between indoor and
outdoor units.
7.
The refrigeration
system does not
function correctly.
Check for leaks or restrictions.
With ammeter. Pressure gauge
or surface thermometer.
-Repair refrigeration system and
charge refrigerant if necessary.
CONTENTS
Содержание HAF 12
Страница 10: ...2 4 PRODUCT DATA SHEET SM HAFRPM 1 A 3 GB HAF7 9 12 Matching GCN7 ONG3 9 ONG3 12 Waiting For SII CONTENTS...
Страница 14: ...4 3 OUTLINE DIMENSIONS SM HAFRPM 1 A 3 GB 4 5 Indoor Unit ONG3 9 ONG3 12 CONTENTS...
Страница 45: ...8 1 WIRING DIAGRAMS SM HAFRPM 1 A 3 GB 8 WIRING DIAGRAMS 8 1 Indoor Unit HAF 7 HAF 9 HAF 12 CONTENTS...
Страница 46: ...8 2 WIRING DIAGRAMS SM HAFRPM 1 A 3 GB 8 2 Outdoor Unit CON 7 8 3 Outdoor Unit GCN 7 GCN 9 GCN 12 CONTENTS...
Страница 47: ...8 3 WIRING DIAGRAMS SM HAFRPM 1 A 3 GB 8 4 Outdoor Unit ONG3 9 ONG3 12 CONTENTS...
Страница 48: ...9 1 ELECTRICAL CONNECTIONS SM HAFRPM 1 A 3 GB 9 ELECTRICAL CONNECTIONS 9 1 HAF 7 HAF 9 HAF 12 CONTENTS...
Страница 54: ...12 3 CONTROL SYSTEM SM HAFRPM 1 A 3 GB 12 3 Main PCB Controller 12 3 1 Display CONTENTS...
Страница 93: ...14 9 EXPLODED VIEWS AND SPARE PARTS LISTS SM HAFRPM 1 A 3 GB 14 9 Outdoor Unit GCN 9 12 RC CONTENTS...
Страница 96: ...14 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM HAFRPM 1 A 3 GB 14 12 Outdoor Unit GCN 9 12 ST CONTENTS...
Страница 99: ...14 15 EXPLODED VIEWS AND SPARE PARTS LISTS SM HAFRPM 1 A 3 GB 14 15 Outdoor Unit ONG3 9 ONG3 12 RC CONTENTS...