ELECTRICAL DATA
SM GCD030 1-A.0 GB
8.
ELECTRICAL DATA
8.1
Single Phase Units
Model
PNX 30
SX 30
CKD 30
DLS 30
Power Supply
1 PH ,220-240VAC ,50HZ
Connected to
Outdoor
Maximum Current
15A
15A
15A
15A
Inrush Current
45 A
Starting Current
15 A
15A
15A
15A
Circuit Breaker
25 A
Power Supply Wiring no
х
cross section
3 X 2.5 mm²
Interconnecting cable no
х
cross section
4X 2.5 mm²
(a) Inrush current is the current when power is up (charging the DC capacitorsat outdoor unit
controller).
(b) Starting current is the current when starting the compressor.
NOTE
:
Power wiring cord should comply with local lows and electrical regulations requirements.
CONTENTS
Содержание CKD 30 DCI
Страница 38: ...7 2 SOUND LEVEL CHARACTERISTICS SM GCD030 1 A 0 GB SX 30 CKD 30 FAN SPEED LINE HI ME LO CONTENTS ...
Страница 41: ...9 1 WIRING DIAGRAMS SM GCD030 1 A 0 GB 9 WIRING DIAGRAMS 9 1 Indoor Unit PNX 30 DCI INDOOR UNIT CONTENTS ...
Страница 42: ...9 2 WIRING DIAGRAMS SM GCD030 1 A 0 GB 9 2 Indoor Unit SX 30 DCI CONTENTS ...
Страница 43: ...9 3 WIRING DIAGRAMS SM GCD030 1 A 0 GB 9 3 Indoor Unit CKD 30 DCI 9 4 Indoor Unit DLS 30 DCI CONTENTS ...
Страница 82: ...14 3 EXPLODED VIEWS AND SPARE PARTS LISTS SM GCD030 1 A 0 GB 14 3 Indoor Unit PNX 30 DCI CONTENTS ...
Страница 84: ...14 5 EXPLODED VIEWS AND SPARE PARTS LISTS SM GCD030 1 A 0 GB 14 5 Indoor Unit SX 30 DCI CONTENTS ...
Страница 89: ...14 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM GCD030 1 A 0 GB 14 10 Outdoor Unit GCD 030 CONTENTS ...