1.3. EqUIPEMENT SAFETY DATA
Safety Data
R407C
Toxicity
Low
In contact with skin
Liquid splashes or sprays may cause freeze burns. Unlikely to be hazardous by skin absorption.
However, R407C may be slightly irritant and, if liquid, it has a strong degreasing effect. Flush contaminated skin
areas with running water. If it comes into contact with fabrics, the liquid refrigerant will cause them to freeze and
adhere to the skin. Carefully remove the contaminated clothing since it might adhere to the skin and cause freeze
burns. Contact a doctor if the affected skin areas are reddened or irritated.
In contact with eyes
Vapours have no effect. Liquid splashes or sprays may cause freeze burns. In these cases rinse your eyes with
running water or with a solution for eye lavages for at least 10 minutes. Immediately contact a doctor.
Ingestion
Very unlikely to occur. If this should be the case, it may cause freeze burns. Never induce vomiting.
Keep the patient awake. Make him rinse his mouth with running water and make him drink about 1/4 of a litre.
Immediately contact a doctor.
Inhalation
R407C: High concentration levels of its vapours in the air can produce an anaesthetic effect, including the loss of
consciousness. Particularly severe exposures may cause heart arrhythmia and sometimes prove to be also fatal.
At high concentrations there is a danger of asphyxia due to a reduced oxygen content in the atmosphere. In these
cases take the patient to the open air, in a cool place and keep him at rest. Administer oxygen, if required. Apply
artificial respiration if breathing has ceased or if it has become irregular. In case of heart failure immediately ap-
ply cardiac massage. Immediately contact a doctor.
Further Medical Advice A symptomatic and supportive therapy is generally suitable. A heart sensitisation has been observed in some
cases, as a result of exposures to particularly high concentrations. In the presence of catecholamines (such as for
example adrenaline) in the blood flow, it has increased the irregularity of the cardiac rhythm and then caused the
heart failure.
Long-term exposure
R407C: A lifetime study which has been conducted on the effects inhalation may have on rats at 50,000 ppm
has shown the onset of benign tumours of the testicle. These remarks suggest that there is no danger for human
beings if they are exposed to concentrations below the occupational limits or equal to them.
Occupational expo-
sure limits
R407C: Recommended limits: 1,000 ppm v/v
8 hours TWA.
Stability
R407C: Not specified.
Conditions to avoid
Use in the presence of exposed flames, red heat surfaces and high humidity levels.
Hazardous reactions
Possibility of violent reactions with sodium, potassium, barium and other alkaline substances.
Incompatible materials: magnesium and all the alloys containing over 2% of magnesium.
Hazardous decompo-
sition products
R407 C: Halogen acids deriving from thermal decomposition and hydrolysis.
General precautions
Avoid the inhalation of high concentrations of vapours. The concentration in the atmosphere shall be kept at the
minimum value and anyway below the occupational limits. Since vapours are heavier than air and they tend to
stagnate and to build up in closed areas, any opening for ventilation shall be made at the lowest level.
Breathing protection
In case of doubt about the actual concentration, wear breathing apparatus. It should be self-contained and ap-
proved by the bodies for safety protection.
Storage Preservation
Refrigerant containers shall be stored in a cool place, away from fire risk, direct sunlight and all heat sources,
such as radiators. The maximum temperature shall never exceed 45°C in the storage place.
Protection clothes
Wear boots, safety gloves and glasses or masks for facial protection.
Behaviour in case of
leaks or escapes
Never forget to wear protection clothes and breathing apparatus. Isolate the source of the leakage, provided that
this operation may be performed in safety conditions. Any small quantity of refrigerant which may have escaped
in its liquid state may evaporate provided that the room is well ventilated.In case of a large leakage, ventilate
the room immediately. Stop the leakage with sand, earth or any suitable absorbing material. Prevent the liquid
refrigerant from flowing into drains, sewers, foundations or absorbing wells since its vapours may create an as-
phyxiating atmosphere.
Disposal
The best procedure involves recovery and recycle. If this is not possible, the refrigerant shall be given to a plant
which is well equipped to destroy and neutralise any acid and toxic by-product which may derive from its dispo-
sal.
Combustibility features R407C: Non flammable in the atmosphere.
Containers
If they are exposed to the fire, they shall be constantly cooled down by water sprays.
Containers may explode if they are overheated.
Behaviour in case
of fire
In case of fire wear protection clothes and self-contained breathing apparatus.