Airvent UV-C FiltAir 

Instruction Manual

Cleaning the UV-C Reactor Surface

The counter on the unit’s control panel shows the operating 

time of the unit. It is recommended to clean the UV-C tubes and 
the UV-C reactor chamber every 2000 hours. To do this, remove 
the top door after unplugging the unit. To remove, first unscrew 
the top of the two M5 safety screws on the right side of the unit 

(seen from the front) with an Allen key 3 (supplied with the unit) 

and push the door upwards by approximately 3 cm and then it 
can be lifted off. During cleaning, it is advisable to wipe the UV-C 
tubes and the inner surface of the UV reactor space with a cloth 
dampened slightly with alcohol.

Attention! 

The reactor space must not be opened by the user. It 

may only be opened by a professional trained by Airvent.

Replacement of UV-C Lamps

UV tubes must be replaced every 8000 hours (annually with con-
tinuous operation). After inserting new UV lamps, the doors need 
to be moved approx. 3 cm higher so that the hooks on the door 
are facing down. Then move the door down as far as it will go. 

(The order is reversed as it was at dismantling.)

 

Removal of the top door

Attention! 

Replacement of UV-C lamps is not permitted by the user and may only be performed by a specialist trained by Airvent. After 

fitting the door, the safety screw must be screwed back on so that unauthorized persons cannot remove the door. We recommend 
documenting the replacement of UV-C lamps on the Maintenance Form at the end of this manual.

Replacing the Top Activated Carbon Filter Plate

It is recommended to replace the activated carbon filter plate on the top of the unit once in a year. To replace, after switching off the 
unit, the UV-C reactor compartment door must be removed as described in the previous sketch. After removing the door, pull out the 
filter holder below the top grille. Lift the clamping grid out of the tray and then remove the used filter plate.

Attention! 

it is recommended to remove the used filter with rubber gloves and a suitable protective mask and dispose of it as hazardous waste.

The tray and clamping grid must be wiped with a disinfectant containing at least 70% ethanol. You can then insert the new filter plate, 

the clamping grille, then place the filter tray back and refit the door as described above.

Attention! 

After the door has been fitted, the safety screw must be screwed back on so that unauthorized people cannot remove the 

door. We recommend documenting the filter change on the Maintenance Form at the end of this manual.

Replacing the top activated carbon filter plate

Содержание UV-C FiltAir

Страница 1: ...UV C FiltAir UV C Air Sterilizer Series for Indoor Applications Instruction Manual ...

Страница 2: ...of the unit 7 Unpacking 7 Removing Doors 7 Separately Packed Accessories 8 Remove the Filter 8 Preparing Mounting Holes 8 Mounting the unit to the wall 9 Inserting UV C Fluorescent Tubes 9 Inserting the Air Filter 9 Fitting the Doors 10 Installation and Use of UV C FiltAir 10 Maintenance 11 Cleaning the Outer Casing 11 Filter Replacement 11 Cleaning the UV C Reactor Surface 12 Replacement of UV C ...

Страница 3: ...housing General information People with reduced physical sensory or mental capabilities or lacking experience and knowledge can only use the unit if it is done under supervision or if they have been instructed on how to safely use it and understand the dangers of using it The unit can be used by children from the age of 8 Children should be supervised to ensure that they do not play with the unit ...

Страница 4: ...tage V 230 Consumption W 133 154 Net weight without lamps and feet kg 35 UV C FiltAir 45 Width mm 820 Depth mm 250 Height mm 2180 Airflow m3 h 100 600 Recommended room area for 5 times hour complete air filtering m2 45 Filter type and size mm M6 756x502 22 Supply voltage V 230 Consumption W 130 206 Net weight without lamps and feet kg 37 UV C FiltAir 75 Width mm 1200 Depth mm 300 Height mm 2180 Ai...

Страница 5: ...et weight without lamps and feet kg 43 UV C FiltAir S 45 Width mm 820 Depth mm 250 Height mm 2370 Airflow m3 h 100 600 Recommended room area for 5 times hour complete air filtering m2 45 Filter type and size mm M6 756x502 22 Supply voltage V 230 Consumption W 130 206 Net weight without lamps and feet kg 50 UV C FiltAir S 75 Width mm 1200 Depth mm 300 Height mm 2420 Airflow m3 h 200 1000 Recommende...

Страница 6: ...irflow created by the UV C FiltAir sweeps down the airborne particles without vor tices and continuously sterilizes the room air through the unit CFD simulation of air moved by a UV C FiltAir placed next to a wall in a room with a ceiling height of 3 m UV C Sterilization In the first phase of operation the device performs mechanical cleaning it removes solid contaminants from the air and in the se...

Страница 7: ...ed to the wall Unpacking The unit must lie on the floor whilst unpacking Remove the protective packaging carefully so that the cardboard does not get damaged The cardboard contains marking patterns on the inside for drilling the mounting holes Removing Doors The unit is delivered with germicide lamps placed separately inside the unit therefore the doors must be removed before the unit can be used ...

Страница 8: ...e marked points indicate where the mounting holes should be drilled on the wall Size C mm UV C FiltAir 15 400 UV C FiltAir 30 600 UV C FiltAir 45 600 UV C FiltAir 75 1050 Place the template on the wall at the designated location of the unit Make sure that the template is meeting the floor so the unit will be installed at the right height Mark the mounting points on the wall with a sharp tool e g a...

Страница 9: ...eds to be placed back to its des ignated place and then it must be firmly fixed to the wall in four places with screws Markthelocationoftheboreholesthroughtheholesonthebacksheetoftheunit Inserting UV C Fluorescent Tubes The fluorescent lamps to be inserted into the socket at the bottom andtopandrotated90degreestotherightorleftuntiltheyclick Pay attention to holding them at the bottom and top with ...

Страница 10: ...d not constitute an obstacle during cleaning Installation and Use of UV C FiltAir UV C FiltAir 45 1 Make sure the doors and safety screws are in place 2 Make sure that air can flow freely at the bottom and top of the unit and that there are no objects on the top of the unit that can obstruct the airflow 3 Connect the machine to the mains and turn on the power switch located on the bottom of the ma...

Страница 11: ...To remove the door after disconnecting the unit unscrew the safety screw on the side of the cover with an Allen key 3 supplied Then shift the door approximately 3 cm in an upward motion then the door can be taken off Attention It is recommended to remove the used filter with rubber gloves and a suitable protective mask and dispose of it as hazard ous waste After turning the filter clips the filter...

Страница 12: ...UV C lamps is not permitted by the user and may only be performed by a specialist trained by Airvent After fitting the door the safety screw must be screwed back on so that unauthorized persons cannot remove the door We recommend documenting the replacement of UV C lamps on the Maintenance Form at the end of this manual Replacing the Top Activated Carbon Filter Plate It is recommended to replace t...

Страница 13: ...orm Date Counter is at Maintenance done by Filter replacement Every 2000 hours or in every 6 months Activated carbon filter replacement Every year UV tubes reactor space cleaning Every 2000 hours UV tubes replacement Every 8000 hours ...

Страница 14: ...bon impregnated filter material CARBOTEX400 764x185 1 UV C FiltAir 45 Part name Part code pc unit LTC28T8 30W UVC T8 fluorescent lamp LTC28T8 30W UVC T8 4 FP M6 G22 panel filter with metal frame 756x502 22 FP M6 G22 502x756x22 1 UV C FiltAir 45 Activated carbon impregnated filter material CARBOTEX400 764x235 1 UV C FiltAir 75 Part name Part code pc unit LTC28T8 30W UVC T8 fluorescent lamp LTC28T8 ...

Страница 15: ...15 www airvent eu Notes ...

Страница 16: ...www airvent eu ENG Airvent Headquarters 6000 Kecskemét Belsőnyír 150 Hungary Phone 36 30 938 1141 or 36 30 248 1169 Email export airvent hu ...

Отзывы: