background image

airtouch.net.au

Installer

 

Manual

Содержание AirTouch 2

Страница 1: ...airtouch net au Installer Manual...

Страница 2: ...4 Damper RPM Setting 17 5 1 5 Touchpad Temp 17 5 1 6 Reset and Save current system settings 17 5 1 7 Supply Air Sensors 17 5 2 Zone Setting 18 5 3 Grouping Zones 20 5 4 Spill or Bypass 21 5 5 Enabling...

Страница 3: ...ngs 24 5 6 5 Configure AC Fan Speed Options 24 5 6 6 On Duration Time 24 5 6 7 Set AC set point ranges 25 5 6 8 Multiple Ducted Systems 25 5 6 9 Groups in each ducted system 25 5 7 System Info 26 5 8...

Страница 4: ...4 Compatible Brands Compatible Brands...

Страница 5: ...4 Cables Cables with left latch or central latch plugs connect the main control module extension module if applicable console and motorized dampers together 1 5 Supply Air Sensor optional Supply air s...

Страница 6: ...zone dampers and up to two consoles Figure below shows the connection of devices such as the WiFi router AC indoor PCB extension module console and eight dampers to the main module AirTouch 2 Main Con...

Страница 7: ...ted to Modbus line Maximum four gateways can be connected for one AirTouch 2 to control four AC s Please see AC wirings for details in section 6 Main and extension modules can be in different location...

Страница 8: ...oor Unit 1 Indoor Unit 2 Indoor Unit 3 Indoor Unit 4 To Zone Dampers Z1 Z2 Z3 Z4 ZD ZC ZB ZA Z9 ZE ZF ZG Unit Gateway 2 Unit Gateway 3 Unit Gateway 4 Sensors Optional Supply Air Z8 Z7 Z6 Z5 RS 485 B A...

Страница 9: ...four zones Example There could be one or more zones going into a common area such as Kitchen Dining or Family Dining room Work out the total group number Maximum total group number in a system is 16...

Страница 10: ...me 4 2 Remove the two side covers on the main module All LEDs and sockets for zone dampers are exposed 4 3 If the extension module is used connect main module to extension module at E M port on both m...

Страница 11: ...are used connect one to T on the main module and the other to the extension module 4 8 Connect the 24V AC transformer to screw terminals on the main control module If extension module is used connect...

Страница 12: ...base During the installation process the case will have to be opened to mount the console on the wall Follow the steps below to carefully install the console to the wall a Slide the back base to bott...

Страница 13: ...g four screws on the marked positions e Retrieve the console cable from main control module out of the cable hole and plug it into the console f Align the bottom edge of the back base with the bottom...

Страница 14: ...all and make sure the back of front cover is flash against the wall And then push the front cover downwards with two figures holding the top side of the front cover where there are two slots till the...

Страница 15: ...setting spill bypass grouping service and AC These settings are protected by a password which has default value Polyaire but can be changed Touching Installer s button in the Settings list will bring...

Страница 16: ...splayed with barometer icon alongside the AC name on the home screen if Display Control Sensor Temp is ticked This is the temperature the AC unit uses to control its compressor and fan It s not ticked...

Страница 17: ...eated up and use an accurate reference temperature gauge Input the correct value to match the reference gauge If there are two consoles connected in the system they will be automatically identified as...

Страница 18: ...s 100 opening position and the adjustable range is between 5 and 100 with 5 increment The zone settings can be conducted on the touch screen as below a On Installers screen touch Zones menu b Touching...

Страница 19: ...19 Zone Setting...

Страница 20: ...uping can be carried out as follows a In Installers screen touch Grouping to enter Grouping screen 5 3 Grouping Zones b Then touch or button to add or minus zones to the group c Repeat steps b and c t...

Страница 21: ...d spill groups are forced to open the spill groups will be very cold or hot There is no dedicated bypass port Any unused zone ports can be assigned as bypass ports The system will maintain the number...

Страница 22: ...s or can be manually changed The Service Reminder is disabled by default but can be enabled as follows a In the Installer settings screen touch Service to enter the Service screen b Touch the service...

Страница 23: ...aemar and Gree The wiring diagrams for full AC control are in section 6 5 6 0 Group AC s If there are more than two ACs in the system they can be grouped to be turned on or off with one touch Touching...

Страница 24: ...e selected console sensor will not be used for AC control as expected even though the console of AirTouch 2 will show the measured temperature from the console sensor 5 6 5 Configure AC Fan Speed Opti...

Страница 25: ...systems If multiple ACs supply conditioned air to the same ducted system this is classified as one ducted system and all ACs will have the same spill bypass and Turbo settings If each AC has its indep...

Страница 26: ...e and be accessed outside the home Go to WiFi Connection section in the quick access menu to connect the AirTouch 2 to the home router The available WiFi networks will appear Choose the correct one an...

Страница 27: ...pp cannot be used over the internet Tick Enable Hotspot and configure the hotspot as required The online update will not be available In some extreme situations where the WiFi is not required the WiFi...

Страница 28: ...e group buttons to turn groups on or off to check if the dampers are correctly connected by feeling the air at the outlet d The Turbo group can be tested by selecting the relevant chosen group as Turb...

Страница 29: ...tandard AC Wall Controller from AC Indoor Unit if it s not going to be used Refer to relevant AC Gateway Drawings below to connect Gateway Refer to Dip Switch settings if applicable on the Gateway Dra...

Страница 30: ...first and then power up AirTouch 2 Or power them up at the same time 4 If AirTouch 2 sensors are used for AC temperature control Settings on the Daikin AC wall controller Set thermostat sensor to the...

Страница 31: ...Z6 Z5 RS485 Gateway N L 24 VAC B A E M To Extension Module T To Touchscreen Console Z1 Z8 To Zone Ports 1 4 Supply Air Sensors RS 485 To AC Gateways 24 VAC To Power Supply To Damper Motors To Damper...

Страница 32: ...sor to the remote controller Remove it after the setting if the Daikin wall controller is not going to be used Otherwise set Daikin AC wall controller as sub controller Settings on the gateway set pos...

Страница 33: ...Z6 Z5 RS485 Gateway N L 24 VAC B A E M To Extension Module T To Touchscreen Console Z1 Z8 To Zone Ports 1 4 Supply Air Sensors RS 485 To AC Gateways 24 VAC To Power Supply To Damper Motors To Damper...

Страница 34: ...ault position gateway as Slave Make sure all wires are connected properly 2 Initialise the AC Unit with Panasonic AC Wall Controller connected The Panasonic wall controller can be wired to R1 and R2 i...

Страница 35: ...ndoor PCB Gateway Address Setting S2 S3 Gateway As 10000000 000 1 01000000 000 2 11000000 000 3 00100000 000 4 657213 Note 1 0 Off 1 On 2 This applies to firmware version after V2 3 Master Slave Selec...

Страница 36: ...e dipswitches on the gateway at their default position Make sure all wires are connected properly 2 Initialise the AC Unit with Panasonic AC Wall Controller connected The Panasonic wall controller can...

Страница 37: ...Gateway N L 24 VAC B A E M To Extension Module T To Touchscreen Console Z1 Z8 To Zone Ports 1 4 Supply Air Sensors RS 485 To AC Gateways 24 VAC To Power Supply To Damper Motors To Damper Motors AirTo...

Страница 38: ...sition Make sure all wires are connected properly If the gateway address is not 1 follow the Gateway Address Setting table to set the address 2 Initialise the AC Unit with Panasonic AC Wall Controller...

Страница 39: ...Z6 Z5 RS485 Gateway N L 24 VAC B A E M To Extension Module T To Touchscreen Console Z1 Z8 To Zone Ports 1 4 Supply Air Sensors RS 485 To AC Gateways 24 VAC To Power Supply To Damper Motors To Damper...

Страница 40: ...lise the AC Unit with Toshiba AC Wall Controller connected The Toshiba wall controller can be wired to A and B in parallel with the gateway 3 Remove the Toshiba wall controller if it is not to be used...

Страница 41: ...teway Indoor Type Settings S1 S4 Indoor Type 00xx 0000 Not Defined 10xx 0000 VRF SMMSi 01xx 0000 RAV 11xx 0000 VRF SMMS SHRM Two Core cable stripped wires field prepared AC Indoor PCB Gateway Address...

Страница 42: ...and restart the AC and AirTouch 2 4 If AirTouch 2 sensors are used for AC temperature control Settings on the AC wall controller Set thermostat sensor to the remote controller Go to Service Function...

Страница 43: ...ting S1 S4 Gateway As 0111 0000 Slave 1111 0000 Master Two Core cable stripped wires field prepared AC Indoor PCB Gateway Address Setting S3 Gateway Address 10000001 1 01000001 2 11000001 3 00100001 4...

Страница 44: ...er settings and select the proper temperature sensor for AC control Restart the AC and gateway first and then power up AirTouch or power them up at the same time If AirTouch sensors are not used and t...

Страница 45: ...Z6 Z5 RS485 Gateway N L 24 VAC B A E M To Extension Module T To Touchscreen Console Z1 Z8 To Zone Ports 1 4 Supply Air Sensors RS 485 To AC Gateways 24 VAC To Power Supply To Damper Motors To Damper...

Страница 46: ...their default position Make sure all wires are connected properly 3 Initialise the AC Unit with ME AC Wall Controller connected 4 Remove the ME wall controller if it is not to be used after commission...

Страница 47: ...er RS485 A B HomeKit S A2 E M T Z1 Z2 Z3 Z4 Z8 Z7 Z6 Z5 B2 B1 L N RS485 A B S3 S4 S1 S A1 2 Supply Air Sensors E M Extension Module T Touchscreen Z1 Z8 Zone Dampers L and N 24V AC Power Supply RS485 A...

Страница 48: ...way to ON 1 Then restart the AC and gateway first and then power up AirTouch 2 Or power them up at the same time 4 If AirTouch 2 sensors are used for AC temperature control Settings on the LG AC wall...

Страница 49: ...he gateway Master Slave Settings S1 S4 Gateway As 0000 0000 Slave 1000 0000 Master AC Indoor PCB Gateway Address Setting S3 Gateway Address 10000001 1 01000001 2 11000001 3 00100001 4 657219 Note 0 Of...

Страница 50: ...ntroller connected The MHI wall controller can be wired to X and Y terminals in parallel with the gateway If the MHI wall controller is not going to be used after commissioning and the return air sens...

Страница 51: ...al RS485 A B HomeKit S A2 E M T Z1 Z2 Z3 Z4 Z8 Z7 Z6 Z5 B2 B1 L N RS485 A B S3 S4 S1 S A1 2 Supply Air Sensors E M Extension Module T Touchscreen Z1 Z8 Zone Dampers L and N 24V AC Power Supply RS485 A...

Страница 52: ...control Settings on the Hitachi AC wall controller Set thermostat sensor to the remote controller Go to Function Setting find Item C8 and change its value to 01 Remove it after the setting if the Hita...

Страница 53: ...olyaire Provided with the gateway Master Slave Setting S1 S4 Gateway As 0000 0000 Slave 1000 0000 Master Two Core cable stripped wires field prepared AC Indoor PCB Gateway Address Setting S3 Gateway A...

Страница 54: ...default position Make sure all wires are connected properly 2 Change mode 10 value to 01 via AC Wall Controller 3 If AC Wall Controller is not going to be used after commissioning change mode 00 value...

Страница 55: ...Plus S A1 2 V 1 V 24 VAC B A CN1 COM BMS2 Gateway ID Setting S2 ID 0010 Braemar Gree Two stripped wires with two pin plug From Polyaire AC Indoor PCB Gateway Address Setting S1 Gateway Address 1000 1...

Страница 56: ...lectrical box cover 3 In default AC will use its own return air sensor as control sensor Installers can set the AC control thermistor to an AirTouch 2 sensor by going to AC setup in Installer s Settin...

Страница 57: ...ch 2 Plus S A1 2 V 1 V 24 VAC Y X Heat Mode Compensation Setting S2 Value 0100 0 00 0111 4 00 Two stripped wires field prepared AC Indoor PCB Gateway Address Setting S1 Gateway Address 1000 1 0100 2 1...

Страница 58: ...Unit If AirTouch 2 sensors are used for AC temperature control Settings on the AirTouch 2 choose from Control Thermistor list in the Installer s AC Setup Settings from the Samsung wall controller Go...

Страница 59: ...657211 RS485 Cable from Polyaire Provided with the gateway Two stripped wires field prepared AC Indoor PCB Gateway Address Setting S1 Gateway Address 1000 1 0100 2 1100 3 0010 4 657229 Note 1 0 Off 1...

Страница 60: ...he AC Unit with Samsung AC Wall Controller connected 3 If AirTouch 2 sensors are used for AC temperature control Settings on the AirTouch screen choose from Control Thermistor list in the Installer s...

Страница 61: ...Touchscreen Z1 Z8 Zone Dampers L and N 24V AC Power Supply RS485 AC Gateway AC Gateway F3 F4 F3 F4 AirTouch 2 Plus S A1 V1 V2 V1 V2 657211 RS485 Cable from Polyaire Provided with the gateway Master S...

Страница 62: ...As 0000 0000 Slave 1000 0000 Master Four Core cable stripped wires field prerpared AC Indoor PCB Gateway Address Setting S3 Gateway Address 10000001 1 01000001 2 11000001 3 00100001 4 657217 Note 1 0...

Страница 63: ...gs Provided with YCJ A002 From Haier AC Indoor PCB Gateway Address Setting S1 Gateway Address 1000 1 0100 2 1100 3 0010 4 657222 Note 0 Off 1 On BM1 1 2 0 1 SW1 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 Note 0...

Страница 64: ...2 is to control more than one AC unit gateways for multiple ACs can be joined in serial as shown in the wiring above Each gateway will be set with a unique gateway address and as required for the AC...

Страница 65: ...h 2 app supports is iOS 8 0 When mobiles and AirTouch 2 are all connected to the same WiFi and with the same band the AirTouch 2 app will run straight away and the control interface will come up If th...

Страница 66: ...Code FFFF or FFFC Gateway is connected but AC is not powered or the communication to AC is lost Error Code FFFE Communication to gateway is lost Gateway switch setting issue or faulty gateway 8 Troubl...

Страница 67: ...67...

Страница 68: ...ications and procedures are correct at time of publication but are subject to change without notice Please read the instructions before installing this Zone Control System Polyaire Pty Ltd does not ac...

Отзывы: