Airton 409709 Скачать руководство пользователя страница 1

INSTALLATION AND INSTRUCTION MANUAL

& MAINTENANCE

MONOBLOC MOBILE COLD & HOT AIR CONDITIONER

Ref: 409709 – Type: YPS-12HW/3

HOTLINE

1

Translated from French to English - www.onlinedoctranslator.com

Содержание 409709

Страница 1: ...INSTALLATION AND INSTRUCTION MANUAL MAINTENANCE MONOBLOC MOBILE COLD HOT AIR CONDITIONER Ref 409709 Type YPS 12HW 3 HOTLINE 1 Translated from French to English www onlinedoctranslator com...

Страница 2: ...t Safety Instructions p 4 1 Overview of the air conditioner p 6 2 Installation requirements p 7 3 Control display panel and remote control p 8 4 Instructions for use p 10 5 Drainage p 14 6 Maintenance...

Страница 3: ...irectives Do not puncture any component of the refrigeration circuit If the appliance is installed operated or stored in an unventilated room this must be able to prevent the stagnation of possible le...

Страница 4: ...ing it Turn off and unplug the air conditioner before uninstalling cleaning replacing parts or when not in use Follow the instructions in this manual for cleaning the air conditioner The voltage of th...

Страница 5: ...n upright position for at least 24 hours before starting it Use the appliance only on a horizontal and flat surface to avoid any water leakage and to ensure the correct functioning of the compressor P...

Страница 6: ...pipe 1 5 meters 8 Window recessed panel 9 Remote control and its housing 10 Rear air intake grille 11 Upper filter 12 Power cable winding hook for storage 13 Carry handle 14 Air outlet to connect to t...

Страница 7: ...can be placed horizontally or vertically See diagram above Adjust opening distances to bring both ends of the assembly into contact with the window frame and secure the various components of the assem...

Страница 8: ...time 7 Remote control receiving window CONTROL PANEL DISPLAY SCREEN 1 COOL lamp 2 OSCILLATION air flap sweeping indicator activated 3 FAN SPEED indicator 4 DRY indicator 5 Temperature operating time i...

Страница 9: ...ed on the air scavenging flaps are automatically active FAN SPEED button Successively press the button on the remote control or from the control panel to choose the desired fan speed 3 positions high...

Страница 10: ...pressing the button on the control panel or the remote control COOLING COOL MODE Press the MODE button on the control panel remote control to select COOL mode Warning light Press the keys on the contr...

Страница 11: ...or remote control to select DRY mode Warning light lights up on the air conditioner display Beforehand remove the cap and drain plug on the back of the air conditioner for dehumidifying water Insert...

Страница 12: ...to activate the ignition delay time from 0 24H Where Programming No 2 The air conditioner running ON press the button on the control panel once or the remote control to set the stop time Press the key...

Страница 13: ...er or the water outlet to the sewer or another drainage area to drain the water Refer to the instructions in chapter 5 Drainage below After draining the water the air conditioner will automatically re...

Страница 14: ...y flow into the water tank Note During drainage the air conditioner may be tilted slightly backwards Once the water has been evacuated BE CAREFUL to reposition the drain plug and its cap before restar...

Страница 15: ...r Manually remove the filter by gently pulling Place the filters in the warm water about 40 C added neutral detergent dry them in the shade after cleaning Proceed with the reverse operations to replac...

Страница 16: ...ce the air conditioner on a flat and rigid surface avoid any surface that causes shaking The air conditioner is not placed on a suitable installation surface Too noisy The compressor does does not wor...

Страница 17: ...r is responsible for disposal of this type of waste by throwing it in a recycling point specific to electrical and electronic waste Selective collection and recycling of electrical equipment helps pre...

Отзывы: