Страница 1: ...User Manual AIRTOCHECK Monitor...

Страница 2: ...OF KEYS AND COMPONENTS 8 INSTALLATION 9 DISPLAY CLARIFICATION 10 OPERATING THE MENU 13 NAME MENU 13 CHANGE CURRENT NAME AND ENTER NEW NAME 13 EDIT CURRENT NAME 13 RESULTS MENU 14 COPY MEMORY 14 PRINT...

Страница 3: ...21 SMS TEL NO 1 22 SYSTEM MENU 23 P1 RELAY 23 CALIBRATION 24 REPROGRAM 24 SND DELAY 24 RECALL DEFAULT 24 SET DEFAULT 25 LANGUAGE 25 SETTINGS 25 DATE 26 TIME 26 SENSORS 27 HIGH LEVEL 27 LOW LEVEL 27 L...

Страница 4: ...the SD card If you want to transfer data to the SD card in the meantime you can do so manually see Menu RESULTS Copy memory Always do so before copying measurement data to your PC so that no measurem...

Страница 5: ...all safety instructions in this manual Safety guidelines and warnings These safety guidelines must be strictly observed during all stages of the monitor s installation operation and maintenance Failur...

Страница 6: ...hed cable Only ever use this accompanying cable The metal parts of the monitor must be connected to the earth connection to prevent electric shocks Always use a system with such an earth connection If...

Страница 7: ...o read negative pressure values in real time via the app or website and generate measurement reports for more information please go to www airtocheck com The sensors used result in very stable and exa...

Страница 8: ...measurement values 5 to 35 Limit B measurement values 10 to 35 Limit C measurement values 5 to 40 Limit D measurement values 10 to 40 Limit E measurement values to be determined 3 Connection point fo...

Страница 9: ...emoving the hose continually press the upper ring but bear in mind that if you press to hard the hose and or monitor may get damaged Only ever use the originally supplied hose s When measuring a secon...

Страница 10: ...re is no upper and lower limit for the negative pressure which means the system is unable to send out alarms Printer on off This section enables you to turn the printer on off Once you have switched o...

Страница 11: ...the monitor being hooked up to mains voltage AC 220v Measurement value update status Internet status Measurement value update status If the Internet connection is ever disconnected the monitor will su...

Страница 12: ...ows the monitor using its battery SD card status memory status If no SD card has been installed the memory indicator will indicate that the internal memory is currently being used In the above image 1...

Страница 13: ...menu 2 Press the Enter key 13 to open the NAME menu The blinking cursor is now positioned on the first line 3 Press key 11 4 Press key 11 3 times 5 Press key 12 until the cursor reaches _ 6 Press the...

Страница 14: ...isappeared 5 Press the Menu key 9 3 times to return to the home screen Make sure that you have carefully read the instructions on How to handle measurement data on page 4 To copy the measurement data...

Страница 15: ...now be printed from the starting date and time you have just selected onwards and the monitor will return to its home screen Show memory Viewing the registered measurement values on the screen Please...

Страница 16: ...monitor to switch to its battery and when it switches back to the mains current afterwards and once the monitor s memory is full Alarm messages are submitted once the set delay time has passed A tota...

Страница 17: ...ion 1 Press the Menu key 9 to open the menu 2 Press key 12 2 times to select the MODEM menu 3 Press the Enter key 13 to open the MODEM menu 4 Press key 11 until the RSSI level option is shown 5 Press...

Страница 18: ...available if the Limited menu feature has been turned off and is intended for Airtocheck service staff 1 Press the Menu key 9 to open the menu 2 Press key 12 2 times to select the MODEM menu 3 Press t...

Страница 19: ...key 9 to open the menu 2 Press key 12 2 times to select the MODEM menu 3 Press the Enter key 13 to open the MODEM menu 4 Press key 11 until the PIN code modem option is shown 5 Press the Enter key 13...

Страница 20: ...alarm messages sent to 3 different phone numbers Please note A SIM card and SMS or SMS Data subscription is required for this feature Always use international notation to enter phone numbers i e 44 7...

Страница 21: ...u 4 Press key 11 until the SMS tel no 2 option is shown 5 Press the Enter key 13 3 times 6 Press key 11 7 Press key 12 until the cursor is positioned over DEL If no phone number has been added yet you...

Страница 22: ...removed 9 Press keys 9 10 and or 12 to move to the right digit and press the Enter key 13 to select the desired digit Repeat this procedure until you have entered the desired phone number 10 Press ke...

Страница 23: ...flashing light with horn for acoustic and visual alarms on or off with due observance of the set delay time and the set measuring limits A B C D or E in terms of both negative and positive pressure A...

Страница 24: ...e delay time 8 Press the Menu key 9 2 times to return to the home screen Recall default This option allows you to remove all of the monitor s variable settings and return it to the settings you have s...

Страница 25: ...ntil the Set default option is shown 5 Press the Enter key 13 the current settings will be saved as the default setting and the monitor will return to its home screen Language This feature allows you...

Страница 26: ...screen Time Option of editing the time Please note The monitor does not automatically adjust to daylight savings time Make sure you do so yourself to ensure proper recording of measurement values End...

Страница 27: ...et the desired maximum negative pressure value E See page 8 key 16 Please note The monitor has been calibrated for a measuring range of 1 Pa up to 40 Pa 1 Press the Menu key 9 to open the menu 2 Press...

Страница 28: ...I number IP number Message modem PIN code modem Calibrate Reprogram Recall default Set default Language Settings 1 Press the Menu key 9 to open the menu 2 Press key 12 3 times to select the SYSTEM men...

Страница 29: ...h printing size Battery back up 4 hours Pressure range 40 6 Pascal Display 20x4 character display Internal memory 30 days if P1 and P2 are active 60 days if only P1 is active Included Manual power cab...

Страница 30: ...negative pressure machine in your projects to be able to stabilise the negative pressure Airtocheck offers you the option of adding an external relay block for the monitor to use to switch said additi...

Страница 31: ...ser bears all responsibility for ensuring that these updates are carried out and that the product is running on the most recent version of all software If an issue with the product can be resolved by...

Страница 32: ...provide the services covered by this warranty Defects that may be solved by installation of software or software updates that are not supplied by Airtocheck but may be purchased freely in the market...

Страница 33: ...to receive said support according to their warranty in terms of the warranty period and supplied services and the like will be assessed in accordance with the regulations that apply in the territory...

Страница 34: ...R DEALER Asgro Van der Voort 13b Nijverheidsweg 3401 MC IJsselstein 31 0 30 2202980 ijsselstein asgrovandervoort com www asgrovandervoort com Airtocheck B V Diakenhuisweg 27 2033 AP Haarlem 31 0 88 56...