Hitch/Coupler
The EZ-Latch coupler features a simple-to-use latching
mechanism� Hooking up is as easy as dropping the
coupler on to your hitch ball� Simply make sure that the
coupler is properly lined up with the ball, then lower
the coupler� The coupler will automatically open and
latch into place when lowered onto the hitch ball� To
disengage coupler, pull up on latch and raise coupler
off of hitch ball� Return the coupler latch to the latched
position to ensure that coupler is ready to be latched
again�
The coupler features a strong composite handle, If the
handle does get damaged or becomes missing, the
coupler is still completely operational until the handle
can be replaced� Replacement parts can be purchased
through your Airstream Dealer� See additional
information included in your owner’s packet�
WARNING
Always make sure coupler is properly attached and
latched before towing.
Liquid Petroleum Gas (LPG)
Fill Valve
The
LPG tanks are equipped with fill valve connections
RV Type I Acme
� The large, green, nylon swivel nut is
a right-hand thread and is designed for hand operation
only�
The valve features an internal spring-loaded module
that will not allow gas to flow from the cylinder until a
positive seal has been made at the connection� The
valve outlet has 1-5/16 in� Acme threads on the outlet
exterior, and female POL, left-handed threads on its
interior� This feature allows for connection of the new
wrenchless, right-handed, Acme RV connection while
still accommodating the standard left-handed POL
fittings used for filling propane cylinders.
The mating, green swivel nut and brass nipple also
incorporate new features: the green nylon nut swivels
on a black bushing that is heat-sensitive� Between 240
and 300°F, the bushing will yield (melt) allowing the
spring-loaded module in the valve to push the brass
nipple back (approximately 1/4 in�), closing the module
and stopping the flow of gas from the cylinder. Inside
the brass nipple is a flow-limiting device designed
to sense excessive gas flow. If an excessive flow is
sensed, the flow-limiting device shuts the flow down
to a maximum of 10 SCFH (Standard Cubic Feet per
Hour) or less� This is also referred to as the bypass
flow.
Содержание REI Co-op Special Edition
Страница 4: ...2023 REI Special Edition NOTES NOTES...
Страница 6: ...2023 REI Special Edition 1 2 Introduction NOTES NOTES...
Страница 24: ...2023 REI Special Edition 3 12 General Information NOTES NOTES...
Страница 26: ...Floor Plans And Specifications 4 2 2023 REI Special Edition Floor Plan REI Special Edition...
Страница 82: ...Maintenance 8 20 2023 REI Special Edition Breaker label content may vary Standard 30 Amp Circuit Breaker Layout...