![Airstream Rangeline 2023 Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/airstream/rangeline-2023/rangeline-2023_owners-manual_2879308107.webp)
9-21
120VAC, 30A, 60Hz
INPUT
OUTPUT
GROUND BUSS
MAIN
30A
AIR COND.
20A
(EMS CTL'D)
BOILER ELEM.
(EMS CTL'D) 20A
INVERTER
(EMS THROT)20A
GFIC RECEPT'S
15A (GFIC) w/
(EMS CTL'D
GALL. RECEPT.)
BOILER ELEMENT (DIRECT RELAY CTL)
AC COMP. (RV-C CTL)
GALLEY RECEPT. (DIRECT RELAT CTL)
MICROWAVE (DIRECT RELAY CTL).
EMS SHED ORDER
LABEL:
MAIN BREAKERS
1ST:
2ND:
3RD:
4TH:
20
20
30
20
GFI
15
EMS/RVC MONITOR
RVC1
RVC2
DISP
Inverter Earth
Terminal
8Ga.
Torque = 23in/lb
EQ
EQ
INVERTER OUTPUT CAN BE ENERGIZED TO THE MAIN BREAKER
ON THE INVERTER MAIN BREAKER INPUT. VERITIFY THE
INVERTER IS "OFF" WHEN SERVICING THE MAIN BREAKER BOX.
15
20
INV.OUTPUT
15A RECEPT'S
(EMS CTL'D
MICRO)
INV. OUTPUT
RETURN 20A
LABEL:
INVERTER BREAKERS
5TH:
CHG'R THROTTLED (RV-C CTL)
SEE DWG # 953729S11, (J14-4d)
SEE DWG # 953728S1 (SC1, RV-C)
SEE DWG # 953729S11 REF (J16-1)
DIP SWITCH SETTING
ON
2
1
SUB-PANEL BREAKERS
1) DRAWING SHOWS ALL OPTIONS.
2) GFIC breakers "Self Test and Lockout" need input
power to reset the breaker switch to the "ON" position.
3) Inverter's output has two breakers located in the
main breaker box. (1st. is a 30Amp input breaker which feeds a 2nd 20Amp output breaker, which then feeds the inverter loads.
4) C.S. = Curb Side, R.S. = Road Side.
EQ
EQ
EQ
TRN1
MD1
DANGER!
VERIFY INVERTER AND MAIN POWER IS DISABLED BEFORE SERVICING!
30-Amp 120-Volt Schematic - Canada
Содержание Rangeline 2023
Страница 1: ...2 0 2 3 R a n g e l i n e SCAN ME O w n e r s M a n u a l...
Страница 4: ...NOTES NOTES 2023 Rangeline NOTES NOTES...
Страница 6: ...2023 Rangeline 1 2 Introduction NOTES NOTES...
Страница 26: ...2023 Rangeline 3 12 General Information NOTES NOTES...
Страница 28: ...Floor Plans And Specifications 4 2 2023 Rangeline Floor Plan Rangeline...
Страница 76: ...2023 Rangeline 7 10 Ram Promaster Van NOTES NOTES...
Страница 100: ...Maintenance 9 14 2023 Rangeline 12 Volt Model Schematic MAIN CABIN AREA J4 13a J4 13b MD1 G12 M 1 BAT MULT TRN1...
Страница 101: ...Maintenance 2023 Rangeline 9 15 12 Volt Model Schematic SEE ROOF TV CAP BRN YEL 4 2a WHT 150 SW SW SW SW SW SW...
Страница 102: ...Maintenance 9 16 2023 Rangeline 12 Volt Model Schematic SW SW...
Страница 103: ...Maintenance 2023 Rangeline 9 17 12 Volt Model Schematic 1 4 7 10 2 5 8 11 3 6 9 12 13 14 15 1 4 7 2 5 8 3 6 9...
Страница 114: ...2023 Rangeline 9 28 Maintenance NOTES NOTES...
Страница 118: ...428 West Pike Street P O Box 629 Jackson Center OH 45334 0629 Phone 937 596 6111 Fax 937 596 7939 www airstream com...