Testing the Smoke/CO Detector
Test it at least once a week� PRESS and HOLD the
TEST/SILENCE button 3-5 seconds until the unit starts
to alarm� During testing, you will see and hear the
following sequence:
• The Horn will sound 3 BEEPS, pause, 3 BEEPS�
The Power/Smoke LED flashes Red and the CO
LED will be OFF�
• Next the Horn will sound 4 BEEPS, pause, 4
BEEPS� The Power/Smoke LED will be OFF and
the CO LED flashes Red.
Clean the Smoke/CO Alarm at least once a month:
gently vacuum the outside of the alarm using your
household vacuum’s soft brush attachment or use a
can of compressed air to clear away dust and debris
(sold at computer or office supply stores). Follow
manufacturer instructions for use� Never use water,
cleaners, or solvents since they may damage the unit�
If the alarm becomes contaminated by excessive dust
or debris causing unwanted alarms, replace the unit
immediately�
WARNING
Test Units in your touring coach after the vehicle
has been in storage, before each trip, and at least
once a week while in use. If the alarm ever fails to
test correctly, have it replaced immediately. If the
alarm is not working properly, it cannot alert you
to a problem. Failure to test units used in RVs as
described may remove your protection.
This Carbon Monoxide Detector Is Not
• Designed to detect any gas other than Carbon
Monoxide�
• To be seen as a substitute for the proper servicing of
fuel-burning appliances�
• To be used on an intermittent basis, or as a portable
alarm for spillage of combustion products from fuel-
burning appliances�
NOTE
This Carbon Monoxide detector is designed for
indoor use only. Do not expose to rain or moisture.
Do not knock or drop the alarm. Do not open
or tamper with the alarm as this could cause
malfunction. The detector will not protect against
the risk of Carbon Monoxide poisoning when the
batteries are dead or missing. The alarm will only
indicate the presence of Carbon Monoxide gas at
the sensor. Carbon Monoxide gas may be present
in other areas.
Important Safety Precautions
• Ideally, it is recommended that a Carbon Monoxide
detector should be installed in or near every room
that has a fuel burning appliance such as any room
heaters, water heaters, cookers, grills, etc�
• Ensure that the alarm horn can be heard by all those
who are intended to hear it� Seek medical help if it
is suspected that a user of the RV is suffering from
Carbon Monoxide poisoning�
• If the alarm sounds, make sure to investigate the
problem� Ignoring the alarm may result in sickness,
injury or death� (CO may be present even if nothing
is seen or smelled by the user�)
• Room spaces should be well ventilated when
household cleaning supplies are used as these may
cause a false alarm�
• Alarm should be tested once per week� If further
details are required, which do not appear in this
for support�
WARNING
Activation of your Carbon Monoxide alarm’s
audible horn indicates the presence of Carbon
Monoxide that can kill you. Leave the area
immediately!
Содержание Rangeline 2023
Страница 1: ...2 0 2 3 R a n g e l i n e SCAN ME O w n e r s M a n u a l...
Страница 4: ...NOTES NOTES 2023 Rangeline NOTES NOTES...
Страница 6: ...2023 Rangeline 1 2 Introduction NOTES NOTES...
Страница 26: ...2023 Rangeline 3 12 General Information NOTES NOTES...
Страница 28: ...Floor Plans And Specifications 4 2 2023 Rangeline Floor Plan Rangeline...
Страница 76: ...2023 Rangeline 7 10 Ram Promaster Van NOTES NOTES...
Страница 100: ...Maintenance 9 14 2023 Rangeline 12 Volt Model Schematic MAIN CABIN AREA J4 13a J4 13b MD1 G12 M 1 BAT MULT TRN1...
Страница 101: ...Maintenance 2023 Rangeline 9 15 12 Volt Model Schematic SEE ROOF TV CAP BRN YEL 4 2a WHT 150 SW SW SW SW SW SW...
Страница 102: ...Maintenance 9 16 2023 Rangeline 12 Volt Model Schematic SW SW...
Страница 103: ...Maintenance 2023 Rangeline 9 17 12 Volt Model Schematic 1 4 7 10 2 5 8 11 3 6 9 12 13 14 15 1 4 7 2 5 8 3 6 9...
Страница 114: ...2023 Rangeline 9 28 Maintenance NOTES NOTES...
Страница 118: ...428 West Pike Street P O Box 629 Jackson Center OH 45334 0629 Phone 937 596 6111 Fax 937 596 7939 www airstream com...