5-11
WARNING
The GFCI circuit breaker provides protection only
to the circuit to which it is connected. It does NOT
provide protection to any other circuit.
GFCI Breaker Test
Perform this test on the GFI circuit breaker each month
and record the date�
A
B
Push To
Test
1�
With handle A in “ON” position, press PUSH TO
TEST button B�
2� Handle A should move to TRIP position, indicating
that GFCI breaker has opened the circuit�
3�
To restore power move handle A to “OFF” and then
to “ON“.
If the device remains on when the Test button is
pushed, the GFCI is not working properly or has
been incorrectly installed (wired improperly)� If your
GFCI is not working properly, call a qualified, certified
electrician who can assess the situation, rewire the
GFCI if necessary, or replace the unit�
NOTE
All GFCI breakers implement an auto self-test
function, however, Airstream recommends a
manual test be conducted every month.
2� For proper grounding, connect the short ground
lead to a grounded outlet box or to a cold water
pipe� When no water pipe is available, drive a
metal rod two feet into the ground and attach the
ground lug to it, thus, providing the unit with proper
grounding�
NOTE
When the three-pronged plug can be used,
there will be no problems with proper polarity or
grounding with a properly wired shoreline outlet.
NOTE
When operating with city power, make very certain
that the service is 120-volt and not 240-volt.
To operate self-contained, simply disconnect the power
supply cable�
Ground Fault Circuit Interrupter (GFCI)
Most states require trailers with exterior 120-volt
receptacles and receptacles close to a water sources,
such as a faucet, to have a ground fault-circuit
interrupter� When properly installed, the GFCI circuit
breaker provides reliable overload and short-circuit
protection, plus protection from ground faults that might
result from contact with a
HOT
load wire and ground�
WARNING
The GFCI circuit breaker will NOT reduce shock
hazard if contact is made between a HOT load wire
and a neutral wire or 2 HOT load wires.
Each GFCI circuit breaker is calibrated to trip with
a ground current of 5 milliamperes or more� GFCI
breakers require 120V power to be present for it to
be reset� Since most persons can feel as little as 2
milliamperes, a distinct shock may be felt if the need
for protection exists� However, the shock should be of
such short duration that the effects would be reduced
to less than the normally dangerous level� However,
persons with acute heart problems or other conditions
that can make a person particularly susceptible to
electric shock may still be seriously injured�
While the GFCI circuit breaker affords a high degree of
protection, there is no substitute for the knowledge that
electricity can be dangerous when carelessly handled
or used without reasonable caution�
Содержание Caravel 2023
Страница 1: ...2 0 2 3 C A R A V E L O w n e r s M a n u a l SCAN ME...
Страница 4: ...2023 Caravel NOTES NOTES...
Страница 6: ...2023 Caravel 1 2 Introduction NOTES NOTES...
Страница 24: ...2023 Caravel 3 12 General Information NOTES NOTES...
Страница 26: ...Floor Plans And Specifications 4 2 2023 Caravel Floor Plans 16RB Caravel 19CB Caravel 20FB Caravel 22FB Caravel...
Страница 48: ...2023 Caravel 5 20 Interior NOTES NOTES...
Страница 58: ...2023 Caravel 6 10 Exterior NOTES NOTES...
Страница 88: ...Maintenance 8 22 2023 Caravel Standard 30 Amp Circuit Breaker Layout Breaker label content may vary...
Страница 100: ...428 West Pike Street P O Box 629 Jackson Center OH 45334 0629 Phone 937 596 6111 Fax 937 596 7939 www airstream com...