background image

En-6

Perform wiring so that water does not enter this unit 

along the external wiring. Always install a trap to the 

wiring or take other countermeasures. Otherwise it will 

cause trouble, electric shock, or fire.
Confirm the name of each unit and name of each 

terminal block of the unit and connect the wiring in 

accordance with the directions given in the manual so 

that there is no incorrect wiring. Incorrect wiring will 

damage the electric parts and cause smoke and fire.

When installing the connection cables near a source 

of electromagnetic waves, use shielded cable. Other-

wise, a breakdown or malfunction could result.

When wiring between the outdoor unit, indoor unit, 

 

and touch panel controller, refer to the indoor unit and 

outdoor unit installation manuals.

Always connect both ends of the 

 

earth (ground) con-

nection of the transmission cable.

Install the disconnect switch to the easily accessible 

 

location.

Install the fuse (5A) to the L line of power supply cable.

 

L N

X1 X2 Y1Y2Y3

L N

X1 X2 Y1Y2Y3

L N

X1 X2 Y1Y2Y3

L N

X1 X2 Y1Y2Y3

L N

X1 X2 Y1Y2Y3

L N

X1 X2 Y1Y2Y3

1Ø 50/60Hz

100-240V

L N

X1 X2

1Ø 50/60Hz

100-240V

L N

X1 X2

X1 X2

Z1 Z2

H1 H2

Outdoor unit 

(Master)

Touch panel 

controller

Indoor unit

Power 

supply

Power 

supply

Power 

supply

Power 

supply

Power 

supply

Power 

supply

Power 

supply

Transmission

Power

Supply

Transmission

Wired remote 

controller

Wired remote 

controller

Touch panel 

controller

Fuse (5A)

Switch

(Disconnect switch)

2 remote 

controllers

Wireless 

remote 

controller

Fuse (5A)

Switch

(Disconnect  

switch)

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

2 remote 

controllers

Trans-

mission

Trans-

mission

Trans-

mission

Trans-

mission

Trans-

mission

Trans-

mission

Trans-

mission

Trans-

mission

Remote 

controller

Remote 

controller

Remote 

controller

Remote 

controller

Remote 

controller

Remote 

controller

Power

Supply

Power

Supply

Power

Supply

Power

Supply

Power

Supply

Power

Supply

Power

Supply

Wire the transmission cable to any one of the following:

 

Transmission terminal block inside the indoor unit 

 

(Fig. 1)

External terminal block (Field supplied)

 

 (Fig. 2)

Transmission terminal block inside the outdoor unit 

 

(Fig. 3)

1

Fig1 

Touch panel 

controller

Refrigerant 

system 1

Refrigerant 

system 2

2

Fig1 

External terminal block

Touch panel 

controller

Refrigerant 

system 1

Refrigerant 

system 2

3

Fig1 

Touch panel 

controller

Refrigerant 

system 1

Refrigerant 

system 2

Installation method

51 51 

Install the switch box in advance to the wall to which 

 

the touch panel controller is to be installed.

Installation procedure

(1) 

Verify that the 

 

power supply cable and transmission 

cable are wired to the switch box.

Peel the cable covering.

 

Decide the path the 

 

power supply cable and transmis-

sion cable are to follow up to the terminals of the touch 

panel controller.

After passing the 

 

power supply cable and transmis-

sion cable through the specified holes of the instal

-

lation plate, fix the installation plate to the switch box 

using screws.

Adjust the tilt of the installation plate by installing the 

accessory washers.

In addition, pass the 

 

power supply cable and trans-

mission cable through the wiring hole of the rear 

cover and fix the rear cover using the tapping screws 

(M4 x 8mm, 2 screws) supplied with the installation 

plate.

Next, fix the rear cover to the wall using the 2 acces

-

 

sory screws (M4 x 20mm) and accessory washers.

Fix the cables at 2 places by binders.

 

7

Provide a surplus of 5mm or more from the end of the 

 

covering of the cable and fix the part which is fixed by 

the binders.

Fix the 

 

power supply cable and transmission cable to 

their respective terminal so that there is no mistake.

Tightening torque

Power supply 

cable

1.2 to 1.8 N 

 m  

(10.7 to 15.9 lbf 

 in)

Transmission  

cable

0.8 to 1.2 N 

 m  

(7.1 to 10.6 lbf 

 in)

Содержание UTY-DTGY

Страница 1: ...H PANEL CONTROLLER CONTR LEUR DE PANNEAU CONTACT CONTROLADOR DE PANEL DE CONTACTO CONTROLADOR DE PAINEL DE TOQUE For authorized service personnel only Uniquement r serv aux techniciens agr s S lo para...

Страница 2: ...o leak con tains suspended carbon fibers or flammable dust or volatile inflammables such as paint thinner or gaso line If gas leaks and settles around the unit it can cause a fire Do not use the unit...

Страница 3: ...h ground the unit Transmission cable LONWORKS compatible cable External input cable Use cable in accordance with local rules for cable LONWORKS is registered trademark of Echelon Corporation in the Un...

Страница 4: ...the screwdriver This will cause an accident The front cover and rear cover are connected by wir ing When disassembling be sure that the wiring is not stretched Do not touch this unit s circuit board...

Страница 5: ...minals TM201 CN411 CN412 L N X1 X2 K1 K2 K1 K2 CH1 CH2 TRANSMISSION EXTERNAL INPUT TM201 VRF LONWORKS Transmission terminal Screw Size M3 Earth Ground terminal Screw Size M3 External input terminal Sc...

Страница 6: ...nly CH1 can be used CH2 cannot be used Wiring 555555 WARNING Before starting installation work turn off the power of this unit and the connection destination Do not turn on the power again until insta...

Страница 7: ...Remote controller Remote controller Remote controller Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Wire the transmission cable to any one of the following...

Страница 8: ...E POWER 666 CAUTION Check that the power supply voltage is within the specified range If a power supply voltage outside the specification is input it will cause trouble Recheck the wiring Incorrect wi...