![Airspan MicroMAX Скачать руководство пользователя страница 90](http://html.mh-extra.com/html/airspan/micromax/micromax_hardware-installation-and-users-manual_2879137090.webp)
MicroMAX Hardware Installation User Guide
Page 90
Commercial in Confidence
UWB-D00068 Rev J
Figure 86 - BSDU + Poly BSR
The following table describes the connections:
Table 30 - Description
Item
#
Description
Manufacturer
Manufacture
P/N
Quantity Comment
1 Copper wire 0 AWG
N/A
N/A
N/A
Ground resistance must be
less than 5 Ohm.
Cable should have UL
approval.
2 SFTP Cat-5E
Shielded
N/A
N/A
N/A
up to 100 meters in length
3 Ring terminal
N/A
N/A
N/A
Stud H (1/4), Diameter to
match the copper wire
diameter used
4 Circuit Lightning
protection for BSR
Polyphaser IX
series
IX-
2H1L1DC48-
IG
1
Installed with BSR