AirSynergy3 Equipment Installation Guide
Page 33 | Commercial in Confidence SYN-UG-018
5 Power System Connection
Caution:
Hazardous voltage!
Before working, ensure that the power is removed
from the power connection cables. When the system is powered on,
do not
touch the power terminals
.
Tools Required:
The tools required for the connection of the PSU are: knife,
small flat blade screw driver (electrical insulated shaft recommended), medium
cross-head screw driver, pliers, small side cutters, tweezers (or fine blade long
nose pliers)
Figure 40 – Tools required to connect the PSU
5.1 Run cables from the PSU to the AirSynergy
5.1.1 The drop cable installation. If the drop cable is to be passed through glands and/or down the
centre of a lamp post or other structure, the drop cable can be cut leaving sufficient length for ease of
termination
. (The typical cable supplied is 30m in length and other length options are available)
With the power supply placed at the selected installation location, trim the cable to the length for neat
installation while allowing sufficient length to strip and prepare the cable ends.
Note
:
It is good practice to label both ends of the drop cable to identify which
AirSynergy unit it is connected to. This is especially important where multiple
AirSynergy units are installed on the same pole/tower.
Note:
It is good practice to leave a spare loop of drop cable (approximately 0.5m
of cable). This will allow for ease of wiring to the power supply and will allow the
cable to be re-terminated if necessary in the future.