![Airspan AirHarmony 4000 DC Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/airspan/airharmony-4000-dc/airharmony-4000-dc_installation-manual_2879123035.webp)
AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide
UGD-D01123
Airspan Commercial and Internal Use
29
1.
Select the location on the pole to mount the AirHarmony-4000. You can attach the
AirHarmony-4000 to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter.
2.
Insert the clamp straps through the slots in the mounting plate passing them through
the pole clamps.
3.
Insert the clamp bands by passing them through the slots in the mounting plate, in four
(4) places.
Note:
The clamp bands are not supplied by Airspan and are the responsibility of the
installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on
the mounting plate.
4.
Tighten the clamp bands with large flat screwdriver.
Figure 11: Mounting plate mounted
4.2.3
Mounting on a Wall
The following images show the wall mount assembly.
Caution:
Take care to install the Pole/Wall mounting plate in the correct orientation.
Verify that the mounting pins are facing upwards as shown below.
1.
Position mounting plate against the wall with mounting pins facing up. Be sure to
position the wall mounting plate
straight with
level mounting
to ensure the unit sits
evenly.
2.
Mark the wall through the holes on the wall mount at the required height.