![Airspan AirHarmony 4000 DC Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/airspan/airharmony-4000-dc/airharmony-4000-dc_installation-manual_2879123033.webp)
AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide
UGD-D01123
Airspan Commercial and Internal Use
27
3.
Drill a minimum 7/16
hole to
accept the 3/8-16 threaded rod.
4.
Thread the 3/8-16 threaded rod into the provided clinch-nut attached on the Pole/Wall
mounting plate.
5.
Holding the mounting plate (with the attached threaded rod) pass the 3/8-16 threaded rod
through the drilled hole in the pole.
6.
Install on the exposed thread that protrudes from pole a flat washer, split washer, and
the a 3/
-16 hex nut and tighten.
7.
Insert the clamp bands by passing them through the slots in the mounting plate, in three
(3) places.
Note:
The clamp bands are not supplied by Airspan and are the responsibility of the
installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on
the mounting plate.
8.
Tighten the clamp bands with large flat screwdriver.
Figure 8: Mounting plate on pole