AirHarmony-1000 Installation Guide
UGD-D01006
Airspan Commercial and Internal Use
39
6 Cable Connections
Hazardous voltage!
Before working, ensure that the power is removed from the power
connection cables. When the system is powered on,
do not touch the power
terminals
.
6.1 Connecting the AC/DC Power Converter to
AirHarmony-1000
The DC Connector comes pre-assembled on the AC/DC Converter, as shown below:
Figure 32: AC/DC Converter with DC power connector
6.1.1 Power Cable Preparation
The Power cable is connected to the AirHarmony-1000 using a Gland connector assembled on the
bottom panel of the unit.
1. Remove the connector by unscrewing the body from the AirHarmony-1000, using the Gland
wrench.
2. Pass the pre-assembled connector through the tail nut, gland seal, body and rubber seal of
the connector casing as shown below. Do not tighten the tail nut.
Figure 33: DC Power connector pre-assembled on converter
Note
The connector is attached inside the weather protected area of the enclosure and
is not subjected to water/moisture therefore the use of
die-electric gels is not required.
3. Connect the DC power cable connector to the female connector outlet inside the unit.