Mounting the Base Station Radio (BSR)
41
MOUNTING AC/DC POWER CONVERTER
Mounting the AC/DC Power Converter
The AC/DC Power Converter is to be mounted horizontally in a rack (ETSI or 19“)
Rack mounting
The AC/DC Power Converter is designed for mounting in a standard 19-inch (48.3 cm) ETSI
equipment rack or telco rack with 1-rack unit (1-U) of vertical rack space. Mounting bracket
flanges are provided for mounting the AC/DC Power Converter into the cabinet, in its kit.
Therefore, all that is required for mounting the AC/DC Power Converter is to attach the AC/DC
Power Converter front-rail mounting brackets to the rack's mounting rails using the four M5-
mounting screws and plastic cup washers.
To rack-mount the AC/DC Power Converter:
1.
Determine the rack rail holes (left and right side) that will be used for attaching the chassis.
2.
Insert four nuts into the rack's rail holes you designated in Step 1. These nuts are housed
in Tinnerman clips, which allow you to fasten them into the rail holes. To insert the
Tinnerman clips, hold the clips, squeeze them, and then insert them into the rail hole.
3.
Carefully insert the AC/DC Power Converter into the rack, aligning the AC/DC Power
Converter's mounting bracket holes with the rack rail holes.
4.
Insert the M5-mounting screws, with plastic washers, into the AC/DC Power Converter
mounting bracket holes, on each side, as shown in figure below. In this way, the chassis is
supported until you tighten the chassis screws.
5.
Tighten the M5-mounting screws to fasten the chassis to the cabinet.
Connecting Redundant PS Unit
When required an additional PS unit is available (optional) for redundancy. This hot-swappable unit
is designed for ease of installation.
To install an additional PS unit
1.
Check that the recessed on/off switch is in the
off
position
2.
Determine the location to mount the redundant PS unit in the AC/DC Power Converter's
chassis housing (usually to the left on the presently installed unit).
3.
Carefully slide the unit on the rail tray until flush with front of AC/DC Power Converter's
chassis housing.
4.
Secure the unit by turning the Latch Lock screw, using a flat screw driver
5.
Set the DIP switches (located on the back of the PS unit) to the on position for all 5
switches.
Содержание 605-0000-742
Страница 11: ...Introduction 7 Maximum Output TX Power MicroMAX Maximum Output TX Power ...
Страница 24: ...605 0000 742_MicroMAX_Hardware_Installation_Rev_G 20 ...
Страница 46: ...605 0000 742_MicroMAX_Hardware_Installation_Rev_G 42 ...
Страница 49: ...Cabling the BSR 45 ...
Страница 51: ...Cabling the BSR 47 ...
Страница 61: ...Cabling the BSR 57 When working with BSDU ...
Страница 64: ...605 0000 742_MicroMAX_Hardware_Installation_Rev_G 60 SDA 4SDC PolyPhaser BSR ...
Страница 65: ...Cabling the BSR 61 BSDU PolyPhaser BSR ...