If you intend to use the unit in an area exceeding 3,000 square feet in size or if
you have rooms that are segregated, you should consider an additional AirSource
3000 unit. However, do NOT place more than one air treatment unit in the 
same room.

Important:

Placing the unit too close to a wall or on certain material may contribute

to a localized dusting effect because the unit can pull particulate out of the air
and certain materials generate a charge that attracts the particles. Formica and
laminated wood may be more likely to develop this effect. For best results, place
the unit on bare wood, such as a stained oak bookcase or place an insulating
material such as paper, wood, hard rubber, or Mylar between the unit and the
surface it sits upon. Avoid placing the unit on metal, plastic, wool, fur, carpet,
silk, or nylon, and place it at least 12 inches away from vertical surfaces.
While the unit is very effective at reducing airborne particles from the breathing
space, very heavy particle loads may burden the unit, requiring necessary

maintenance by the AirSource Warranty Service Center to maintain the unit’s
effectiveness. Examples may include heavy tobacco smoke (such as a cigar lounge),
frequent candle burning, use of a kerosene lamp, fireplace, or unvented stove
burning, several long haired pets, and hobbies, such as woodworking and finishing.
Positioning the unit away from these activities should reduce the direct effect on
the unit, while still providing benefit by dropping the particles out of the rest of
the breathing space away from the unit. Dust the unit with a damp cotton cloth —
using water only — as part of your normal cleaning activities. Vacuuming the vents
of the unit will remove most of the dust build up.

Cleaning

Unplug the unit and use a water-dampened cloth to remove dust particles that
may accumulate on the unit. Do not use harsh detergents, abrasives, furniture
cleaner, solvents, or polishes. Do not spray water or cleaners directly on the unit.

Replacing the Photohydroionization

*

Module

To replace the Module:

Step 1.

Switch the unit off.

Step 2.

Remove the old Module by turning the screw counterclockwise and slowly
backing the Module out until it is completely disengaged. Discard the 
old Module.

Step 3.

Insert the new Module into the unit and turn the screw clockwise until
Module is flush with the outer wall. Do not over-tighten.

Step 4.

Switch the unit on. If the light doesn’t come on, check the fit of the
Module and tighten the screw if necessary.

Please contact your AirSource representative to purchase your replacement 
Photohydroionization Module. Item Code #55103.

4

05-198 AS 3000 Manual_ENG  4/13/05  3:01 PM  Page 5

Содержание 3000

Страница 1: ...Owner s Manual AirSource 3000 Purification System 2005 Shaklee Corp Distributed by Distribuido por Shaklee Corporation Pleasanton CA 94588 05 198 Rev 04 05 recycled paper papel reciclado ...

Страница 2: ... reduce the risk of electric shock this equipment has a grounding type plug with a third grounding pin Do not operate on a non grounded outlet Use of a two pronged adapter is suitable only if the grounding attachment is properly connected and the circuit is grounded If the plug does not fit into the outlet contact qualified personnel to install the proper outlet Do not alter the plug in any way Av...

Страница 3: ...e date of purchase to be free from defects in materials and workmanship under intended normal use as described in the AirSource 3000 Owner s Manual 2 The Photohydroionization Module included in this System is warranted for a period of one year from the date of purchase to be free from defects in materials and workmanship under intended normal use as described in the AirSource 3000 Owner s Manual A...

Страница 4: ... 1 or 2 to and from the AirSource Warranty Service location at no charge for one year from the date of sale to the initial registered consumer owner Thereafter the postage or transportation cost plus insurance charges to and from the AirSource Warranty Service location must be prepaid The usual time for repair is five to ten business days from the date the system or module is received Getting Star...

Страница 5: ...uent candle burning use of a kerosene lamp fireplace or unvented stove burning several long haired pets and hobbies such as woodworking and finishing Positioning the unit away from these activities should reduce the direct effect on the unit while still providing benefit by dropping the particles out of the rest of the breathing space away from the unit Dust the unit with a damp cotton cloth using...

Страница 6: ...ergy from the ultraviolet UV lamp reacts with oxygen ozone a small amount of moisture in the air and the hydrated Tri metallic Catalyst This reaction creates cleansing ions such as hydroperoxides and superoxide ions which are mixed with the air The treatment of your air includes Suppression of bacteria growth bacteriostatic Suppression of mold growth mycostatic Reduction of odors Reduction of VOCs...

Страница 7: ...ed or wiped up as part of your normal cleaning activities The treatment of your indoor air includes Reduction of airborne particulate matter Reduction of airborne microorganisms Reduction of cigarette smoke Reduction of odors Purification System Work 6 This illustration shows you what you cannot see Nearly all of the particles are sub micron not visible to the naked eye The relatively very large p...

Страница 8: ...d into place do not over tighten the screw If the lamp doesn t work replace with a new Module If the lamp still doesn t work call 1 866 GREAT AIR 1 866 473 2824 Specifications Operational Electron Generation Self limiting high voltage Electron Generator Warranty Three Year Limited Warranty on parts and workmanship Electrical Supply Voltage 120 VAC 60 Hz Power 0 5 amps 55 watts Mechanical Dimension...

Отзывы: