Page
4
of
14
- The Emergency Stop button
MUST ALWAYS BE DEPRESSED AND THE KEY
REMOVED
whenever you are setting up the ride or leaving the control console
unattended.
- The operator must adjust the speed of the arms to the abilities of the players.
- Do not press more than one button at a time.
- If the arms are
OBSTRUCTED
,
RELEASE
the left-right rotation buttons
IMMEDIATELY
.
5. Troubleshooting:
Inside the control box there is a motion controller manufactured by Yaskawa. This electronic
part is responsible for the motion of the sealed arms. Any incorrect usage of the mechanism could
result in Yaskawa producing an
Error Code
, which means the mechanism stops responding to
the operator’s commands.
Most of these error codes are built in safety mechanisms, protecting the electric motor. When
experiencing this sudden stop, our advice is to follow these simple steps:
- Turn the mechanism OFF, then ON with the Main On/Off key. This will reset the
Yaskawa settings and you should be able to resume playing.
-
If that doesn’t help, unlock the top of the Control Box with the supplied triangle key, and
reset the settings manually by pressing the
RESET
button. (see figure below)
CAUTION!
TAKE EXTRA CARE WHEN OPENING
THE CONTROL BOX. DO NOT TOUCH ANYTHING
ELSE BESIDES THE RESET BUTTON.
Issue
Steps to take
Short circuit or ground fault
on the drive output side:
Try connecting the motor directly to the main supply. In case it is
used with an extension cord, make sure not to connect to many
things to the same extension lead.
The motor is operated at low
speed with heavy load:
Make sure you remove the obstacle from the motor that keeps it
stopping. Please note you are not allowed to add anything to the
middle foam of the mechanism. Make sure that when a player is
on the sealed arm the mechanism is stopped and is not moving
forward.
Cycle times of acceleration
/deceleration:
If you are sure that this is the case, and we would need to change
assistance.
Overvoltage:
The motor will give an error code if the input voltage is too high.
Make sure you change the generator to a smaller one.