background image

Содержание 104

Страница 1: ......

Страница 2: ...switch accessed is defined as the unit UNDER TEST while the opposite switch not accessed is defined as the REFERENCE The rotation and position of both switches are displayed on the tester s ASYMMETRY SWITCH POSITIONS indicator SWITCHES INDICATORS POWER SWITCH Controls the application of power to the tester Set to either the LEFT SWITCH or RIGHT SWITCH depending on which side of the aircraft has be...

Страница 3: ...POWER SWITCH AUTO SET MANUAL RUN SWITCH FLAPS LOCKED INDICATOR PHASE ERROR INDICATOR SWITCH POSITION INDICATORS TO SWITCH TO AIRCRAFT ...

Страница 4: ...e right or left flap asymmetry switch Both switches will be tested from this side 2 Connect the test box to the aircraft as indicated Connect the ground clip to the aircraft frame This clip is power ground so a good ground connection is required here Secure cables to prevent damage Check that all items are clear of the flap drive system that the harness will not be damaged when the flaps move CONT...

Страница 5: ...eading edge of A Adjust PHASE ERROR to minimum or nil FLAPS LOCKED shall remain off ERROR PHASE FLAPS LOCKED Connect to LEFT or RIGHT asymmetry switch Set POWER switch accordingly Press and Hold AUTO SET switch to move reference to the next leading edge of A Adjust PHASE ERROR to minimum or nil FLAPS LOCKED shall remain off U SWITCH AIRCRAFT Under test Reference ERROR PHASE FLAPS LOCKED MANUAL RUN...

Страница 6: ... ASYMMETRY SWITCH POSITIONS indicators are matched Monitor the PHASE ERROR and FLAPS LOCKED indicators while flaps are in motion 3 If the FLAPS LOCKED indicator illuminates at any time during the testing this indicates a severe misalignment of the switches leading to a complete loss of the asymmetry signal In this condition the flaps will not run when the asymmetry system is reconnected Repeat the...

Страница 7: ... moved and the ASYMMETRY SWITCH POSITIONS indicators DO NOT match Indicates an out of symmetry condition Perform SET ASYMMETRY SWITCHES procedure FLAPS LOCK indicator is illuminated Indicates a serious out of symmetry condition Perform SET ASYMMETRY SWITCHES procedure Nothing happens when the POWER switch is turned on Check all connections Check ground clip is connected properly Check tester fuse ...

Страница 8: ...n notice to the contrary is given to AMI within ten 10 days of such delivery to customer AMI shall not in any case be liable for any event occurring or defect discovered with regard to said products unless written notice thereof is given to AMI within ONE 1 year of such products delivery to customer Except for the warranty that the products are made in accordance with the specifications therefore ...

Отзывы: