Operating Voltage
By default, the router is configured to enter Standby mode at 9 V. If you want to operate
the router at less than 9 volts, power it on using at least 9 V, launch ACEmanager, go to
Services > Power Management and adjust the Standby mode settings.
The maximum ripple voltage to guarantee analog input accuracy must be 100 mVpp.
Power Specifications
Table C-3: Power Supply Specifications
Pin
Name
Specification
Parameter
Minimum
Maximum
1
VCC
Voltage range
VCC
7 V
36 V
Table C-4: Ignition Sense Specifications
Pin
Name
Current Sink
Specification
Parameter Minimum
Maximum
3
IS
(Input only)
240 kΩ
Input low state voltage
(maximum)
V
IL
—
1.0 V
Input high state voltage
(minimum guaranteed)
V
IH
2.5 V
V
in
Note: If you do not connect this pin to the ignition, you
MUST
connect it to the positive terminal of your power supply or
battery. The device looks for a qualified voltage on this pin as part of the power up sequence. If the device doesn’t see it,