AirLink LX60 Series Hardware User Guide
Rev. 2 June 2021
14
41111782
Figure 2-2: Mounting and Grounding the LX60
For DC installations (with a fixed “system” ground reference), Sierra Wireless recommends
grounding the LX60 chassis to this system ground reference.
A ground wire is supplied with the unit. When using a different ground wire, to ensure a
good grounding reference, connect one end of a short 18 AWG or larger gauge wire with
a ring terminal connector to the ground terminal on the LX60 and connect the other end to
your main grounding point.
The ground terminal comes with an M2.5 × 6 mm screw. You can use a longer M2.5 screw
if the terminal connector on your ground wire requires one. Tighten the grounding screw
to approximately 3.5 in-lb (4 cm-kg).
Figure 2-3: Ground connector
Step 3—Connect the Antennas
Warning:
This router is not intended for use close to the human body. Antennas should be at least
8 inches (20 cm) away from the operator.
Avertissement :
Ce routeur n'est pas destiné à être utilisé à proximité du corps humain. Les
antennes doivent être à au moins 20 cm de toute personne.
176.00 mm
6.93 in.
40.0 mm
1 9/16 in.
Mounting holes
5 mm (.1969 in.)
131.5 mm
5 5/32 in
145.86 mm
5 3/4 in
99.7 mm
3 15/16 in.
Grounding point