Error Code Section
3A4108F
23
Error Code Section
Error codes appear on control board as a
blinking red LED.
1.
Remove two screws (71) and swing
down cover (70a).
2.
Start engine.
3.
Count number of Red LED blinks.
After a fault, follow these steps to restart sprayer:
1.
Correct fault correction
2.
Turn sprayer OFF
3.
Turn sprayer ON
SPRAYER OPERATION
LED BLINKS
N
O
I
T
C
A
N
O
I
T
A
C
I
D
N
I
Sprayer stops. Engine
is running.
Exceeded pressure limit.
1.
Check fluid path for clogs, such as clogged filter.
2.
Use Airlessco paint hose, 1/4 in. x 50 ft minimum.
Smaller hose or metal braid hose may result in
pressure spikes.
3.
Replace transducer if fluid path is not clogged
and proper hose is used.
Sprayer stops. Engine
is running.
Pressure transducer faulty,
bad connection or broken
wire.
1.
Check transducer connection.
2.
Disconnect and reconnect transducer plug to
ensure good connection with control board
socket.
3.
Open prime valve. Replace sprayer transducer
with known good transducer and run sprayer.
Replace transducer if sprayer runs or control
board if sprayer does not run.
Sprayer stops. Engine
is running.
High clutch current.
1.
Check wiring connections.
2.
Measure: 1.2 + 0.2
:
3.
Replace clutch field assembly.
Constant
green LED
RED
BLINKS
2 TIMES
RED
BLINKS
3 TIMES
RED
BLINKS
5 TIMES
Sprayer stops. Engine
is running.
Loss of paint to pump or
severe pressure loss.
1.
Check for empty paint condition, clogged inlet
strainer, failed pump or severe leak.
2.
Reduce pressure and turn pump switch OFF
and ON to restart pump.
ti29354a
across clutch field at 70°F.