background image

Installation of the Airistar

®

 100GT

Examine the Airistar 100GT blower, diffuser and your installation 
location and plan your installation methods.

To mount the blower beneath a table with the provided brackets:
1. Determine the mounting location  

                 

a. Check that power jack and filter door are accessible.)

              b. A pathway for the airduct to the diffuser will also need to 
                  be accomodated.)
2. Use the installation template to locate and pre-drill the screw holes.
3. Install the mounting bracket to the surface.
 

a. Mount with the set screw end of the brackets in the direction 

                 from which you will install the blower unit.
 

b. Leave the screws slightly loose for later adjustments.

4. Loosen the set screws on the mounting brackets and slide the blower 
    into position with the air exit nozzle oriented toward the diffuser.
 

a. Tighten the set screws on the mounting brackets to lock the 

                 blower unit into position.
 

b. Adjust the mounting brackets slightly as necessary and tighten 

                the mounting screws.

Note: Other mounting locations are possible with consideration taken for the power jack, 
          filter door and pathway for the air duct to the diffuser.

To mount the diffuser to the table with the provided mounting brackets:
1. Determine the location and method for mounting the diffuser.
    

Note: There are both large and small mounting brackets provided for multiple 

               mounting options.

2. Use the installation template (provided in kit) to mark the cut out area 
    on the table.
    

Note: Be sure to provide clearance to accomodate the mounting brackets and screws.

3. Check the fit  of the diffuser and brackets into the cut out and determine 
    the cut length of the air duct hose.
4. Cut the air duct hose to length. 

     (The nozzles on the blower and diffuser require approximately a +/- 1/2” tolerance.)

5. Install the air duct hose to the blower and diffuser. Preload but do not 
    tighten the adjustable band clamps.

6. Place the diffuser into position and adjust the mounting brackets to the 
    proper position for your installation.
7. Mark the locations for the mounting screws and drill pilot holes. 

     (Adjust the mounting brackets for the desired positioning.)

8. Install the mounting screws and complete final adjustments.

Note: It the diffuser will be mounted through a table (full perimeter cut-out) the face plate 
         will have to be removed with a security screw driver (spanner) and re-installed after 
         the diffuser is mounted through the table. Call your sales representative or 
         Airistar Customer Service if you have any questions about custom mounting.  

8

7

Содержание 100GT

Страница 1: ...Airistar 100GT Owner s Manual 2007 Airistar 100GT Air Purifier ...

Страница 2: ...circuit breakers Ensure that the air duct connects the blower unit and the diffuser Contact your distributor or Airistar customer service Check if filters need replacing Check for items blocking the air intake grid Check for occlusions or kinks in the air duct connected to the diffuser Check if diffuser controls are set for maximum airflow Unit has reduced airflow 16 100 GT 09 07 SPB ...

Страница 3: ...Describes troubleshooting procedures for the Airistar 100GT Filter Replacement Filter Replacement Notes 1 4 5 6 9 10 10 11 12 15 15 ...

Страница 4: ...100GT Pre filter within your gaming establishment Melt Blown Fiber Filter Activated Carbon Filter 1 14 ...

Страница 5: ...gle towards the patrons to provide an air curtain between smoking patrons and the employee while the air from the rear of the diffuser is directed straight up to provide the employee with purified air Electrostatic Pre filter MERV 8 Activated Carbon Filter Odor and Gas control Pre filter Melt Blown Fiber Filter Activated Carbon Filter E D A B C G F H A Electrostatic Pre filter B Melt Blown Fiber F...

Страница 6: ...pounds Airistar s multipurpose VOC filter helps eliminate unwanted gases and fumes associated with tobacco products MERV 8 Pre filter Our pre filter is MERV 8 pleated media It is designed to remove larger airborne particles in the range of 3 10 microns in size or larger This would include substances such as certain types of bacteria mold and plant spores as well as lung damaging dust By extracting...

Страница 7: ...irectional arrows The pre filter Green goes first with the arrow pointing inside the filter frame The Melt Blown Fiber Filter Yellow installs second again with the arrow pointing inside the filter frame Finally the Activated Carbon Filter Red goes into the filter frame with the arrow pointing inside the filter frame 2 Place the filter frame into the purification unit with the arrow pointing to the...

Страница 8: ...er Filter MBF Activated Carbon Filter Follow the procedures below whenever you replace any of the filters 1 Turn off the unit and disconnect it from all sources of electrical power 2 Allow the blower to stop fully 3 Put gloves on for your protection 4 Unlatch and open the filter door of the unit 5 Pull the filter frame straight out of the unit by the handle 6 Remove filters and place in garbage ba...

Страница 9: ... mounting methods can be adapted to the needs of your particular installation Please consult your sales representative or Airistar Technologies for support with custom installations Information for maintaining and replacing the filters for the Airistar 100GT he Airistar 100GT filters should be changed on a regular schedule The table on the following page lists the part numbers of each filter and th...

Страница 10: ...r to the table with the provided mounting brackets 1 Determine the location and method for mounting the diffuser Note There are both large and small mounting brackets provided for multiple mounting options 2 Use the installation template provided in kit to mark the cut out area on the table Note Be sure to provide clearance to accomodate the mounting brackets and screws 3 Check the fit of the diff...