3.6.2.1
Tools required:
•
A multimeter to measure resistance and voltage.
•
A size T10 Torx screwdriver to remove the access panel.
3.6.2.2
Fuse replacement procedure
-
Lay the
HEPA
Bulle
unit on its side to
clear access to the panel that protects
the electronic components. Make sure
to lay the machine down on a clean, flat
surface. Take precautions to avoid
scratching it.
-
Remove the 4 feet using a Torx
screwdriver.
-
Remove the panel.
Access to F1 fuses (x2):
-
Remove the fuses found in the fuse
holders and replace them.