[email protected] | www.airgain.com | + 1-855-AIRGAIN
6
3. Prior to Installation
• Perform a bench power up and pair with the deployment router
• It is much easier to troubleshoot on a bench prior to installation
• It is highly recommended to connect the AirgainConnect to any router it may
be deployed with and verify the configuration
• Ensure a proper data connection to a device directly connected to the Ethernet
port on the Ethernet Injector
• Verify the gasket is correct for the vehicle/location
• The AirgainConnect can be paired with multiple mounting gaskets for specific
vehicle types.
• Ensure that the supplied gasket supports the deployment vehicle
• Determine the mounting location on the specific vehicle
• Ensure that the roof location is at least 18 inches away from other antennas
• Verify that the mounting location of the Ethernet Injector is within 3 feet of a
grounding point such as the vehicle chassis