background image

Instruction Manual

INSTRUCTION MANUAL

DV245 

(Integral CO

2

 Sensor)

DV245 (Integral CO

2

 Sensor)

Содержание 90001271

Страница 1: ...Instruction Manual INSTRUCTION MANUAL DV245 Integral CO2 Sensor DV245 Integral CO2 Sensor ...

Страница 2: ...2 INSTRUCTION MANUAL DV245 Integral CO2 Sensor ...

Страница 3: ...lter display settings time and date week clock turning the unit off 4 MAINTENANCE Filters Heat recovery cell Fans Troubleshooting Condensing water 5 INSTALLATION Installing the condensing water outlets Measuring tubes 6 TECHNICAL SPECIFICATIONS Technical data supply extract air volumes fan curves sound values main components measurement points dimensions and duct outlets Internal electrical connec...

Страница 4: ...afety switch 9 R model in the figure MAIN PARTS OF THE VENTILATION UNIT Internal humidity sensor behind the electric box Internal carbon dioxide sensor behind the electric box Control panel Carbon dioxide sensor optional Humidity sensor optional VOC sensor Optional Post heating liquid radiator 245 MV VKL Ceiling bushing for electric wires 10 10 11 12 13 14 15 16 5 1 4 7 9 4 3 5 15 1 4 7 9 4 3 2 6 ...

Страница 5: ...nnect button in Adroit Cloud Service section 4 Registration Page is now opened 5 Enter the following information a Device name enter the desired name for the device b User name c E mail address d Password 6 Press the create account button 7 An e mail with your log in details will be sent to the e mail given during the registration process 8 A verification e mail will be sent to the e mail address ...

Страница 6: ...nd continuous ventilation in such a way that people and structures will remain healthy GUARANTEE AND LIABILITY Demands on guarantee and liability are excluded if they are caused by the following reasons Unintended use of the ventilation system and the control unit Improper mounting initial operation and operation Operating the ventilation system with a defective safety system Ignoring advice for t...

Страница 7: ...ative humidity of air and carbon dioxide level graphs Minus allows you to Reduce the value of the selected setting Return to the previous menu item Move from a week view to a one day view in the temperature relative humidity of air and carbon dioxide level graphs Up arrow button takes you upwards in the menu Down arrow button takes you downwards in the menu Statistics button opens the temperature ...

Страница 8: ...nguage time and date system administrator password parental controls if turned on fan settings user profile settings such as the temperature The qualified ventilation installer must complete the fan settings in accordance with the ventilation plan Do not change these settings STARTING THE UNIT If you are starting the ventilation unit for the first time or after a maintenance procedure first connec...

Страница 9: ...ventilation unit using a USB MicroB connector Start the ventilation unit A USB sign will appear on the display of the control cannot be used when it is connected to the computer Transfer the update file you have downloaded onto the ventilation unit Copy the update file HSWUPD BIN Please note Do not alter the file name you have downloaded at the root of the control panel the control panel will be d...

Страница 10: ...e Time and date screen is opened first 1 Use the Plus and Minus buttons to set the hours 2 Press the Right arrow button 3 Use the Plus and Minus buttons to set the minutes 4 The time is now set 5 Proceed to the next phase by pressing the Right arrow button SET THE 24 OR 12 HOUR CLOCK By default the system uses the 24 hour clock If you want to use the 24 hour clock proceed to the next step by press...

Страница 11: ...row button 3 Use the Plus and Minus buttons to set the month 4 Press the Right arrow button 5 Use the Plus and Minus buttons to set the year 6 Press the OK button 7 The date is now set FINISHING UP THE DEPLOYMENT When the basic settings have been completed the acknowledgement screen is opened If you want to continue and make the advanced settings for the ventilation unit press the OK button If you...

Страница 12: ...he normal user level the user s access to some menus is restricted Limited At the limited user level the user has access only to the basic functions of the ventilation units For more information on user levels see chapter 9 User level diagrams When you want to set the system user level proceed as follows 1 The deployment wizard User level screen is opened 2 Use the Plus and Minus buttons to set th...

Страница 13: ... exchanger cell If this occurs you cannot adjust the air flows and the Defrosting figure is shown on the control panel SUPPLY AIR When you want to set the system supply air settings proceed as follows 1 The deployment wizard Fan settings screen is opened 2 Set the supply air quantity as a percentage of the maximum by using the Plus and Minus buttons The fan speed 1 min will change according to the...

Страница 14: ...Home profile by using the Plus and Minus buttons You can adjust the temperature in the range of 10 C 5 C 7 The At home profile supply air temperature is now set 8 Press the Right arrow button 9 The setup screen for the automatic fan speed control based on the relative humidity appears 10 Use the Plus and Minus buttons to select whether the automatic fan speed control based on the relative humidity...

Страница 15: ...ly air temperature for the Away profile by using the Plus and Minus buttons You can adjust the temperature in the range of 10 C 5 C 7 The Away profile supply air temperature is now set 8 Press the Right arrow button 9 The setup screen for automatic fan speed control based on the relative humidity appears 10 Use the Plus and Minus buttons to select whether the automatic fan speed control based on t...

Страница 16: ...ased on the relative humidity appears 8 Use the Plus and Minus buttons to select whether the automatic fan speed control based on the relative humidity is used or not 9 Press the Right arrow button 10 The setup screen for the automatic fan speed control based on the carbon dioxide or VOC content appears 11 Use the Plus and Minus buttons to select whether the automatic fan speed control based on th...

Страница 17: ...e We do not recommend reducing the extract air fan speed 7 The Fireplace function supply air fan speed is now set 8 Press the Right arrow button 9 The screen for setting the profile extract air fan speed appears 10 Set the Fireplace function extract air fan speed as a percentage of the maximum by using the Plus and Minus buttons 11 The Fireplace function extract air fan speed is now set 12 Press t...

Страница 18: ...llows 1 If you want to go back to repair or change a value use the arrow buttons to select the desired line and press the OK button 2 Repeat the selected setup phase or phases until you are satisfied with the settings 3 When you are satisfied with the settings use the arrow buttons to select Start and press the OK button DV245 Integral CO2 Sensor ...

Страница 19: ...e activated These fan symbols indicate the currently used mode Fan and one shaded bar The Away mode is in use Fan and two shaded bars The At home mode is in use Fan and three shaded bars The Boost mode is in use Droplet symbols indicate the relative humidity of air Droplet and one shaded bar A humidity sensor has been installed and the relative humidity CO2 and one shaded bar The carbon dioxide or...

Страница 20: ...dicates the outdoor air temperature Fan speed Indicates the fan speed If the automatic fan speed boost is turned on the set value is shown in brackets first followed by the actual fan speed Cell status Indicates the status of the ventilation unit heat recovery cell The status options are Heat recovery The heat recovery cell heats the air streaming in from outdoors Cooling The heat recovery cell co...

Страница 21: ... brackets first followed by the actual fan speed Cell status Indicates the status of the ventilation unit heat recovery cell Possible statuses are Heat recovery The heat recovery cell heats the air streaming in from outdoors Cooling The heat recovery cell cools the air streaming in from outdoors Cell bypass The inflowing air by passes the heat recovery cell Defrosting The heat recovery cell is bei...

Страница 22: ...The heat recovery cell heats the air streaming in from outdoors Cooling The heat recovery cell cools the air streaming in from outdoors Cell bypass The inflowing air bypasses the heat recovery cell Defrosting The heat recovery cell is being defrosted 4 Press the Right arrow button 5 The second information display for the profile opens This display shows the following information Humidity Indicates...

Страница 23: ...file main view 2 Press the Profile information button 3 Press the Edit button 4 The fan speed setup screen is opened 5 Set the At home profile fan speed as a percentage of the maximum by using the Plus and Minus buttons 6 Press the Right arrow button 7 The temperature setup screen is opened 8 Set the desired supply air temperature for the At home profile by using the Plus and Minus buttons You can...

Страница 24: ...djust the temperature in the range 10 C 5 C The recommended temperature is 15 C or 2 3 C below the room temperature 9 Press the Right arrow button 10 The setup screen for automatic fan speed control based on the relative humidity appears 11 Use the Plus and Minus buttons to select whether the automatic fan speed control based on the relative humidity is used or not 12 Press the Right arrow button ...

Страница 25: ... on the relative humidity appears 11 Use the Plus and Minus buttons to select whether the automatic fan speed control based on the relative humidity is used or not 12 Press the Right arrow button 13 The setup for automatic fan speed control based on the carbon dioxide or VOC level opens 14 Use the Plus and Minus buttons to select whether the automatic fan speed control based on the carbon dioxide ...

Страница 26: ...increase the supply air fan speed in order to obtain a positive pressure at the ventilation zone We do not recommend reducing the extract air fan speed Doing this will help against the back flushing of contaminants into the property 9 Press the Right arrow button 10 The screen for setting the profile extract air fan speed will appear 11 Set the Fireplace function extract air fan speed as a percent...

Страница 27: ...ures and sensors 2 Press the OK button 3 The temperatures summary screen is opened 4 Press the Statistics button 5 A graph is opened describing the indoor air temperature over the last 24 hours 6 To view weekly statistics press the Plus button 7 A graph is opened describing the indoor air temperature over the last seven days 8 You can return to daily statistics by pressing the Minus button 9 You c...

Страница 28: ...pressing the Back button 12 To exit the menu press the Back button VIEWING HUMIDITY AND CARBON DIOXIDE VALUES When you want to view individual humidity and carbon dioxide sensor data proceed as follows 1 Select Settings Temperatures and sensors 2 Press the OK button 3 The temperature and sensors summary screen is opened 4 Press the Right arrow button 5 A screen displaying the maximum humidity valu...

Страница 29: ...ion by pressing the Back button 12 Press the Right arrow button twice 13 A screen displaying the values of the carbon dioxide extract air sensor 1 3 is opened 14 Press the Statistics button 15 15 A graph is opened describing the values from the carbon dioxide sensor that gave the largest carbon dioxide value over the last 24 hours 16 If you want to view weekly statistics press the Plus button 17 A...

Страница 30: ...r replacement interval in months SETTING THE DATE THE FILTER WERE LAST REPLACED This section describes how to enter information in the control panel on replacing the ventilation unit filter Replacing the filter itself is described in the ventilation unit maintenance instructions When you want to set the date when you replaced the ventilation unit filter proceed as follows 1 Select Settings Filter ...

Страница 31: ... as follows 1 Select Settings Filter 2 Press the OK button 3 The filter status summary screen is opened 4 Press the Edit button 5 Press the Right arrow button 6 The Filter status 2 2 screen is opened 7 Set the desired reminder interval in months in the Reminder interval field by using the Plus and Minus buttons You can set the interval value from 1 to 12 months The factory setting is 4 months 8 Pr...

Страница 32: ...t sleep time has elapsed To reactivate the Adroit Digital Controller press any button ADJUSTING THE DISPLAY BRIGHTNESS To set the display brightness proceed as follows 1 Select Settings Display settings 2 Press the OK button 3 The Display settings screen appears 4 Press the Right arrow button 5 The Display settings 2 2 screen appears 6 Use the Plus and Minus buttons to set the display brightness 7...

Страница 33: ...nutes 7 Press the OK button SELECTING THE 24 OR 12 HOUR CLOCK By default the system uses a 24 hour clock If you want to use the 12 hour clock proceed as follows 1 Select Settings Time and date 2 Press the OK button 3 The Time and date settings are opened 4 Press the Right arrow until the display 2 4 opens 5 Press the Minus button The 24 Hour Time setting value is changed to Off 6 Press the OK butt...

Страница 34: ... Use the At home profile Away Use the Away profile Boost Use the Boost profile Blank Do not change the profile NOTE If you change the profile manually when the Week clock is on the selected profile will be active until the Week clock switches to the next profile in the program If the humidity or carbon dioxide sensors control the ventilation they will adjust the fan speed regardless of whether the...

Страница 35: ...s The icons are This icon selects the At home profile This icon selects the Away profile This icon selects the Boost profile 7 Set the other profile changes for the Week clock as described above 8 Press the Settings button 9 The Week clock menu opens 10 Select Save and Quit 11 To exit without saving the weekly program or changes select Cancel and Quit 12 A confirmation display opens 13 Press the O...

Страница 36: ...wing weekly program has been set Mon Fri 08 00 17 00 Away from home Mon Fri 17 00 08 00 At home Sat 08 00 18 00 At home Sat 18 00 21 00 Boost that might be needed for cooking Sat 21 00 Mon 08 00 At home To set the Week clock proceed as follows 1 Open the week clock 2 Select Monday and make the following settings At 8 00 select the Away profile At 17 00 select the At home profile 3 Also make the co...

Страница 37: ...ce during the spring and autumn a high amount of heat gain is coming from the sun but the outdoor air can still have a fairly low temperature So if the supply air goes through the heat exchanger the supply air temperature can be too high Same for the case where the supply air is bypassed and no heat is being recovered the supply air temperature can be too cold However if the supply air temperature...

Страница 38: ... model FILTERS When the maintenance reminder becomes activated check the cleanliness of the filters and replace them if required The Adroit ventilation unit has three air filters Class G4 coarse filter filters insects heavy pollen and other relatively large foreign objects out of the outdoor air Class F7 fine filter filters microscopic pollen and dust particles out of the supply air The coarse fil...

Страница 39: ...minium or plastic cells can be washed To check and clean the heat recovery cell 1 Disconnect the ventilation unit from the mains electricity supply 2 Open the doors of the unit 3 Remove the filters A B C 4 Remove the support grid of the filters 5 Disengage the upper support strip D of the cell 6 Lift and pull the cell E out of the unit 7 If the cell is dirty clean it by immersing it in warm water ...

Страница 40: ...r 10 Close the doors and plug the unit back into the mains 11 The fan has now been checked and cleaned Clean the extract air fan in the same way The extract air fan is located symmetrically on the opposite side of the unit FANS Check the cleanliness of the fans when servicing the filters and the heat recovery cell Clean the fans as required You can clean the fan blades with compressed air or by br...

Страница 41: ...ter 1 Disconnect the ventilation unit from the mains electricity supply 2 Open the doors of the unit 3 Open the heater box by undoing the mounting screws 10 PZ2 screws 4 Remove the quick connector of the heater a Press down the locking device b Pull off the connector 5 Undo the two wing nuts connecting the heater to the ventilation unit 6 Lift the heater out of the ventilation unit 7 To reassemble...

Страница 42: ...ter must be replaced Contact the service centre Message on the user interface Bus fault Problems with the data transfer bus Make sure that the Modbus bus is connected correctly and that the devices connected to it are properly functioning The ventilation unit is not working the control panel is not working Power input to the unit is lost Check Fuse in the fusebox Fuse in the unit The ventilation u...

Страница 43: ...bottom plate of the ventilation unit 5 Push the tension pin downward from below towards the main body 6 Place the valve ball inside the housing of the condensing water outlet 7 Attach the housing to the condensing water outlet 8 Install the second outlet in the same way 9 To reassemble the ventilation unit follow the above steps in reverse order 2X 2x MEASURING TUBES The accessories delivered with...

Страница 44: ...25 9 28 2 LW dB LWA dB A 68 0 71 2 74 1 76 1 79 4 58 0 61 6 64 4 67 4 70 0 56 0 60 4 64 0 66 9 71 1 45 5 50 2 53 4 57 0 59 3 Sound pressure level in decibels A coming through the envelope from the room in which the unit is installed 10m2 sound absorption ADJUSTMENT POSITION AIR FLOWS supply extract Adjustment position 30 40 50 60 100 Air flow l s 132 148 159 179 192 214 214 243 251 282 Air flow m3...

Страница 45: ...ptional Post heating radiator 9 Safety switch 10 Internal humidity sensor behind the electric box DIMENSIONS AND DUCT OUTLETS Dimensions Supply Air Extract Air DUCT OUTLETS Model R Inner diameter of the female collar 250mm 1 Extract air from the apartment to the unit 2 Supply air from the unit to the apartment 3 Outdoor air to the unit 4 Exhaust air flowing outdoors from the unit Model L Inner dia...

Страница 46: ...RD MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V direct current voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal NTC External temperature sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1V volt operating voltage AN I AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output...

Страница 47: ...erature transmitter NTC 4K7 Digital input 1 8 different functions Digital input 2 8 different functions Ethernet connection on top of the unit RJ45 female Maximum 6W Adroit Digital Controller 1W Adroit RH transmitter 0 3 W Adroit CO2 transmitter 1 2 W Voltage 24 VDC POWER SUPPLY MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V direct current voltage DC GND Digital and analog gro...

Страница 48: ...r controlling the pump and solenoid valve VENTILATION UNIT INTERNAL ELECTRICAL CONNECTION 24V 24V direct current voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal 11V1 11 1 V operating voltage AN I AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output P Circulation pump V Solenoid valve Distribution board contr...

Страница 49: ...delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example ELV05006 Stig Wahlström K Condensing water tube Not included in the delivery IP De aerator Not included in the delivery S External electrical junction box for the Adroit units N External NTC sensor for Adroit ventilation units C 24 VDC relay contactor for controlling the pump and the solenoid va...

Страница 50: ...e falls below the winter setting To prevent the risk of condensation in the supply air duct you can set the adjustment of the supply air limit to automatic or manual Automatic The supply air limit is adjusted automatically based on the dew point of the extract air When the supply air temperature falls too low the duct radiator will turn off Manual The supply air limit can be set manually When the ...

Страница 51: ...assembly 60000224 14 Front panel of the base 60000269 24 Adroit Digital Controller optional 90000610 5 Upper sealing strip of the HR cell 60000263 15 Bypass damper 60000270 25 Adroit Humidity Transmitter optional 90000612 6 Fan assembly 60000218 16 Bypass arm 60000271 26 Adroit CO2 Transmitter optional 90000613 7 Post Additional heater 1500W optional 60000223 17 Bypass damper motor 60000207 27 Int...

Страница 52: ...ting as part of a ventilation system has been designed and manufactured to the following specifications 1 Low oltage Directive 2014 35 EU EN 60335 1 2012 A11 2014 EN 62233 2008 2 EMC Directive 2014 30EU EN 61000 6 1 2007 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 61000 6 3 2007 A1 2011 3 Ecodesign Directive 2009 125 EY Commission regulation 1253 2014 EN 13141 7 Annex B EN 308 EN 13141 ...

Страница 53: ...Language Filters Temperatures and sensors Time and date Display settings Professional settings Edit Edit Edit Edit Edit Edit Next reminder Unit information HR cell defrost Save and restore settings Control settings Bypass settings of the HR cell Heating settings Basic fan settings I O and bus settings Lock code and access rights Defrost settings Relay settings Input settings External sensor settin...

Страница 54: ... and used in accordance with the fitting and wiring instructions supplied with each unit Has not been connected to an unsuitable electrical supply Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by Airflow Developments Ltd Has been installed in accordance with latest Building Regulations and IEEE wiring regulations by a recognised c...