background image

Tighten the hanger bracket to the 
outlet box with 2 mounting screws.
(To reduce the risk of fire electric 
shock, or personal injury, mount to 
the outlet box marked acceptable for
fan support and use mounting screws 
provided with the outlet box.)

061128

TM

Turn off the electric power

PAGE: 1 / 3

WARNING:

TO  AVOID RISK OF ELECTRICAL SHOCK. BE SURE TO SHUT OFF 
POWR WHILE INSTALLING OR SERVING THIS FIXTURE.

N O T E :

1. To ensure the success of the installation, be sure to read these instructions and

                 review the diagrams thoroughly before beginning.
             2. All electrical connections must be in accordance with local codes, ordinances, and
                 National Electric Code. If you are not unfamiliar with methods of installing with 
                 electrical wiring, secure the services of a qualified licensed electrician.
             3. Total fan with light kit weigh ( FN52180--8.36 KGS/18.58 LBS) . When using an existing 
                 outlet box, be sure the box is securely attached to the building structure and can support
                 the full weight of the fan. Failure to do so can result in serious injury or death.
             4. Before starting the installation, disconnect the power by turning off the circuit breaker
                 or by removing the appropriate fuse at the fuse box. Turning the power off by using
                 the light switch is not sufficient to prevent electrical shock. 

Installation  Steps :

Fig.1.

Fig.2.

Model No.: #

 

FN 52180

ASSEMBLY  AND  INSTALLATION

INSTRUCTIONS

For Downrod Mount:
Insert the motor wires through the 
canopy and downrod.

Fig.3.

For Ceiling Mount:
Attach the canopy to the housing with 
ceiling mount screws.

For Downrod Mount 
Insert the hanger pin through the 
holes in the collar and downrod. 
Insert the lock pin through the hole 
near the end of the hanger pin until 
it snaps into its locked position. 
Tighten downrod screws on top of 
the fan motor finally.

Hang the fan on hanger bracket, and 
make sure the slot of hanger ball is
into the chip of hanger bracket exactly.

Fig.3-1.

Fig.4.

Fig.5.

Содержание FN 52180

Страница 1: ... particular purpose become void This warranty and any implied warranty including but not limited to any implied warranty of merchantability or fitness for a particular purpose do not cover glass globes light bulbs or finish on any metal portions of the Fan This warranty is in lieu of express warranties The duration of any implied warranty of merchantability or fitness for a particular purpose with...

Страница 2: ... an existing outlet box be sure the box is securely attached to the building structure and can support the full weight of the fan Failure to do so can result in serious injury or death 4 Before starting the installation disconnect the power by turning off the circuit breaker or by removing the appropriate fuse at the fuse box Turning the power off by using the light switch is not sufficient to pre...

Страница 3: ...o the ground wire from the motor with a wire nut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side and the underground conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box PAGE 2 3 NOTE Before installing blade holde...

Страница 4: ...inate most of the wobble Check for wobble after each step 1 Check that all blades are screwed firmly into blade holders 2 Check that all blade holders are tightened securely to motor 3 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 4 Most fan wobble problems are caused when blade levels are unequal Check...

Отзывы: