OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

Models:

CVF-8AC, CVF-8AC50, CVF-6ACAN, CVF-15ACAN, CVF-25ACAN

CVF-8DC, CVF-6DCAN, CVF-15DCAN, CVF-25DCAN

Air SySteMS iNterNAtioNAl, iNC.

829 Juniper Crescent, Chesapeake, Va, 23320

Telephone (757) 424-3967

Toll Free 1-800-866-8100

Fax No. (757) 424-5348

www.airsystems.com.

e-mail: [email protected]

this manual must be read carefully and followed by all persons who have or will have the responsibility 

for using or servicing this equipment. this equipment will perform as designed only if used according 

to the instructions. otherwise it could fail to perform as designed, causing personal injury or death.

WArNiNG

Содержание CVF-15ACAN

Страница 1: ...phone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 www airsystems com e mail sales airsystems com This manual must be read carefully and followed by all persons who have or will have the responsibility for using or servicing this equipment This equipment will perform as designed only if used according to the instructions Otherwise it could fail to perform as designed causing personal ...

Страница 2: ...TEP 3 Install duct on bottom of Saddle Vent STEP 4 Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5 Install duct from blower to 90 elbow STEP 6 Turn on blower or fan Warning For explosive environments follow ANSI API 2015 and 2016 procedures The Saddle Vent is a registered trademark of Air Systems International Inc The Conductive Saddle Vent is covered by...

Страница 3: ... federal state and local agencies DO NOT operate these fan unit in a vertical position or with the flange or guards removed WARNING Fan and blower models with the EX or X designation are the only models approved for use in hazardous locations If volatile or explosive vapors are suspected use Air Systems explosion proof electric blower Model No SVB E8EXP explosion proof in line fan Model No SVF 10EX...

Страница 4: ...the minimum recommended size is 14 AWG up to 25 ft For further information refer to the National Electric Code Tables Article 400 7 Push on off switch to I position on CVF 8AC and CVF 8DC models ProBleM PoSSiBle CAUSe SolUtioN Excessive vibration Air intake blocked Turn fan off and clear debris from intake Possible internal damage Turn off and inspect fan blades shaft and housing for debris damage...

Страница 5: ...D CVF RG 3 DUCT CANISTER LATCHING POST CVF POST 4 ON OFF SWITCH CVF SWITCH 5 POWER CORD ELCB012 6 DUCT CANISTER WITH 6 OF DUCT CVF CAN6 7 DUCT CANISTER WITH 15 OF DUCT CVF CAN15 8 DUCT CANISTER WITH 25 OF DUCT CVF CAN25 9 115 VAC 60Hz MOTOR MTR043CN MOTOR TYPE 1 3 HP 2 47 kw electric 115 VAC 60Hz 2 6 amps Single Speed 3450 RPM Thermally Pro tected Max Ambient Temperature 104 Fahrenheit OUTLET SIZE...

Страница 6: ...RIPTION PART 1 DISCHARGE GUARD CVF FG 2 INTAKE GUARD CVF RG 3 DUCT CANISTER LATCHING POST CVF POST 4 ON OFF SWITCH CVF SWITCH 5 CVF 8AC50 POWER CORD E F STYLE PLUG CEE 7 7 ELCB012EF 5A CVF 8AC50G POWER CORD G STYLE PLUG BS1363 UK ELCB012G 6 DUCT CANISTER WITH 6 OF DUCT CVF CAN6 7 DUCT CANISTER WITH 15 OF DUCT CVF CAN15 8 DUCT CANISTER WITH 25 OF DUCT CVF CAN25 9 220 VAC 50Hz MOTOR MTR043CN50 6 Sys...

Страница 7: ...VF FG 2 12 VDC ELECTRIC MOTOR MTR044CN 3 FAN BLADE ASSEMBLY CVF FAN 4 INTAKE GUARD CVF RG 5 20 AMP SLOW BLOW FUSE ELF022 6 DUCT CANISTER LATCHING POST CVF POST 7 ON OFF SWITCH CVF SWITCH 8 RED BATTERY CLAMP ELA083R 9 BLACK BATTERY CLAMP ELA083B 10 DUCT CANISTER WITH 6 OF DUCT CVF CAN6 11 DUCT CANISTER WITH 15 OF DUCT CVF CAN15 12 DUCT CANISTER WITH 25 OF DUCT CVF CAN25 7 Specifications System Comp...

Страница 8: ... CVF CANA 7 8 HOSE CLAMP SV HC8 8 6 NON CONDUCTIVE DUCT SVH 6 9 15 NON CONDUCTIVE DUCT SVH 15 10 25 NON CONDUCTIVE DUCT SVH 25 11 10 STAINLESS STEEL FLATWASHER FW 10SS 12 RED DUCT CANISTER LID NON CONDUCTIVE CVFCANL 13 3 16 POP RIVET FR3 16XMAL 14 DUCT CANISTER LID STRAP CVF BELT 15 10 32 NUT WITH NYLON INSERT FN1032ESN 16 PLASTIC LATCHING POST CVF POST 8 System Components Non Conductive Duct Cani...

Страница 9: ...t or iNDireCt CoStS eXPeNSeS loSSeS or DAMAGeS AriSiNG oUt oF DeFeCtS iN or FAilUre oF tHe ProDUCt or ANy PArt tHereoF The purchaser shall be solely responsible for compliance with all applicable Federal State and Local OSHA and or MSHA requirements Although Air Systems International believes that its products if operated and maintained as shipped from the factory and in accordance with our operat...

Страница 10: ...10 Notes ...

Страница 11: ...11 Notes ...

Страница 12: ...r Crescent Chesapeake Va 23320 Telephone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com Printed in the U S A Copyright Air Systems International Inc 2018 All Rights Reserved Manual No BLWR043 Rev 6 July 2018 ...

Отзывы: