MODELS

VCDK090C • VCDK130C • VCDK170C

Air Specialties Express, 448 S. Main St., P. O. Box 930040, Verona, WI 53593-0040  Phone: (877)945-9175  Fax: (608)845-6470    www.airspecialties.com

CEILING/WALL-MOUNT
VENTILATORS • 120V

READ AND SAVE THESE INSTRUCTIONS

WARNING

CAUTION

TABLE OF CONTENTS

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.

2.

3.

4.

5.

6.
7.
8.

9.

10.

Use this unit only in the manner intended by the manufac-

turer.  If you have questions, contact the manufacturer at the

address or telephone number listed.
Before servicing or cleaning unit, switch power off at service

panel and lock the service disconnecting means to prevent

power from being switched on accidentally.  When the serv-

ice disconnecting means cannot be locked, securely fasten

a prominent warning device, such as a tag, to the service

panel.
Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes

and standards, including fire-rated construction codes and

standards.
Sufficient air is needed for proper combustion and exhaust-

ing of gases through the flue (chimney) of fuel burning

equipment to prevent backdrafting.  Follow the heating

equipment manufacturer’s guidelines and safety standards

such as those published by the American Society for

Heating, Refrigeration and Air Conditioning Engineers

(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
To reduce the risk of fire, use only metal ductwork.
If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected

to a  GFCI (Ground Fault Interrupter) - protected branch cir-

cuit.
Never place a switch where it can be reached from a tub or

shower.
This unit must be grounded.

1.

2.

3.

For general ventilating use only.  Do not use to exhaust haz-

ardous or explosive materials and vapors.
To avoid motor bearing damage and noisy and/or unbal-

anced impellers, keep drywall spray, construction dust, etc.

off power unit.
Please read specification label on product for further infor-

mation and requirements.



“TYPICAL INSTALLATION”

This sections shows a common installation in new and

existing, frame construction.

-Mounting (new construction)

-Mounting (existing construction)

-Wiring

-Ducting (straight-through blower discharge)

“DUCTING OPTIONS”

-Blower Discharge Positions

-Ducting (right-angle blower discharge)

“USE AND CARE”
“WARRANTY”
“SERVICE PARTS”

This manual is divided into sections as follows:

ASX-11218-A, Page 1

Содержание VCDK090C

Страница 1: ...ent manufacturer s guidelines and safety standards such as those published by the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors To reduce the risk of fire use only metal ductwork ...

Страница 2: ...g tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight Ventilator factory Shipped in horizontal discharge position GRILLE Installs after ceiling finished MOUNTING BRACKETS factory shipped in position for 1 2 ceiling material GRILLE SCREW GRILLE 12 ROUND DUCT UNIT SIZE WIRE CONNECTION YEL...

Страница 3: ...R PURPOSE PERFORMANCE OR OTH ERWISE and in no event shall the Seller be liable for claims based upon breach of express or implied warranty negligence product liability or otherwise for any other damages whether direct immediate incidental foreseeable consequential or spe cial USE AND CARE Ventilator is designed for continuous operation If desired it may be controlled using an on off switch or a so...

Страница 4: ...ange 1 10 999 4701 Nut 1 4 20 8 11 384 9142 Pivot Rod 1 12 384 9132 Damper Blade 1 13 999 0022 Screw 10 x 1 2 6 14 384 9181 Conduit Box 1 15 999 9916 Cable Connector 1 16 999 0040 HHCS 1 4 20 x 7 8 4 17 384 9112 Ceiling Fan Housing 1 18 384 9162 Housing Angle 1 19 384 9212 Perforated Steel Grille 1 20 999 9928 Cover Plate 1 21 901 0740 Screw Pkg 1 7 4 10 11 21 20 18 17 13 12 14 15 16 10 19 2 2 1 3...

Отзывы: