Air Monitor Corporation VOLU-probe/1 Скачать руководство пользователя страница 1

VOLU-probe/1, /3, /4 for Round Ducts

INSTALLATION PROCEDURE

WARRANTY

Air Monitor Corporation (hereinafter referred to as "Seller") warrants that at the time of shipment, products sold
pursuant to this contract will be free from defects in materials and workmanship, and will conform to the
specifications furnished or approved in writing by Seller. No warranty is given that delivered products will
conform to catalog sheets, data sheets, and the like, which are subject to change without notice.

Seller will repair or replace, at its option, any products listed under this warranty which is returned freight pre-
paid to Seller and within the earlier of two (2) years after start-up or twenty-seven (27) months after shipment,
prove upon test and examination by Seller to be defective within the terms of this warranty.  The warranty period
for any item repaired or replaced shall be for the time remaining on the warranty period for the original
components.  Purchaser shall notify Seller in writing of such defect within sixty (60) days of discovery of the
defect.

This warranty does not extend to any product sold by Seller which has been the subject of misuse, neglect,
accident, damage or malfunction caused by interconnection with equipment manufactured by others, improper
installation or storage, or used in violation of instructions furnished by Seller, nor does it extend to any product
which has been repaired or altered by persons not expressly approved by Seller.  Nor does Seller warrant
equipment against normal deterioration due to environment; nor items such as thermocouples, electrodes, and
similar items subject to wear or burnout through usage.  Adjustments for items or equipment not manufactured
by Seller shall be made to the extent of any warranty of the manufacturer or supplier thereof.

Seller shall not be liable for any special or consequential damages or for loss of damage directly or indirectly
arising from the use of the products.

The warranty set forth above is in lieu of all other warranties either express or implied and constitutes the full
extent of Air Monitor Corporation's liability to the customer, or any other party for breach of warranty.  THERE
ARE NO EXPRESS WARRANTIES EXCEPT AS SET FORTH HEREIN.  THERE ARE NO IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, WHICH ARE
PARTICULARLY DISCLAIMED.

INSPECTION & HANDLING

.  VOLU-probes should be carefully inspected for damage prior to installation.  Report

damage to your Freight Department, or contact delivery carrier.

Almost any means of handling can be utilized depending on the length and width of the probes.  Probes may be
handled while in any position; however, it is important not to drop or mishandle the probes such that damage is
done to the sensing holes, tubular members, signal connection fittings, end studs, or mounting plates.

Содержание VOLU-probe/1

Страница 1: ...furnished by Seller nor does it extend to any product which has been repaired or altered by persons not expressly approved by Seller Nor does Seller warrant equipmentagainstnormaldeteriorationduetoenvironment noritemssuchasthermocouples electrodes and similar items subject to wear or burnout through usage Adjustments for items or equipment not manufactured by Seller shall be made to the extent of ...

Страница 2: ...comply with the Minimum Requirements for Installation Page 7 Also refer to the dimensional features Page 4 while using this procedure In the following figure three VOLU probes are shown The angle between each VOLU probe is 60º If two VOLU probes are furnished the angle between probes is 90º The radial dimension R between probes is determined by the formula R2 C 2N where C is the duct circumference...

Страница 3: ...OLU probe 1 and VOLU probe 3 over 10 feet in length require mid span support to eliminate excessive droop or oscillation during operation End support conditions for VOLU probe 1 and VOLU probe 3 are illustrated in Figure 2 FASTENERS VOLU probe mounting plates and gaskets are predrilled for 1 4 mounting fasteners For ducts inaccessible from the inside Air Monitor recommends Type AB 1 4 thread formi...

Страница 4: ...VOLU probe 1 3 4 for Round Ducts Installation Procedure 4 DIMENSIONAL SPECIFICATIONS VOLU probe 1 VOLU probe 3 ...

Страница 5: ...VOLU probe 1 3 4 for Round Ducts Installation Procedure 5 DIMENSIONAL SPECIFICATIONS con t VOLU probe 4 ...

Страница 6: ... or plastic barbed type Refer to the following Figure and Details A B C and D for typical tubing configurations Caution After interconnecting tubing and fitting is completed signal lines should be leak tested prior to operation SIGNAL TUBING Signal tubing for total and static pressure take off connections may be 1 4 O D if the distance from the measuring device to the transmitter is 200 or less VO...

Страница 7: ...ants may require periodic manual or automatic cleaning using compressed air applied to the signal fittings and or removal from the duct or stack for physical cleaning MINIMUM REQUIREMENTS FOR INSTALLATION Note VOLU probe locations shown are NOT ideal They indicate the minimum clearance required from air turbulence producing sources Wherever possible the VOLU probe should be installed where greater...

Страница 8: ...urned to Air Monitor should be returned in its original shipping container if possible If this is not possible ensure equipment is packaged sufficiently to protect it during shipment Caution All damage occurring during transit is the Customer s responsibility List the Return Authorization R A number on the packing list and clearly mark this number on the outside of each shipping container Costs as...