SI-104
Smoke Sensor
User Manual
Страница 1: ...SI 104 Smoke Sensor User Manual ...
Страница 2: ...effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice This product contains some codes from GPL In compliance with GPL agreement AirLive will publish the GPL codes on our website Please go to www airlive com and go to the Support GPL men...
Страница 3: ...let on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera...
Страница 4: ...on 3 1 3 Z WaveTM Message Report 3 1 4 Power Up Procedure 4 1 5 Over The Air OTA Firmware Update 4 1 6 Security Network 5 1 7 Test Alarm 5 1 8 Tamper Switch Feature 5 1 9 Battery Installation 6 1 10 Choosing a Suitable Location 6 1 11 Installation 8 1 12 Z Wave Configuration Settings 9 1 13 Z Wave Supported Command Class 9 1 14 Specifications 10 ...
Страница 5: ......
Страница 6: ...etrofitted into home electronics devices and systems such as lighting home access control entertainment systems and household appliances This product can be included and operated in any Z WaveTM network with other Z WaveTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase rel...
Страница 7: ...ice will wake to receive the setting command from Z WaveTM controller about 20 seconds Remove 1 Have Z WaveTM Controller entered exclusion mode 2 Pressing TEST Button three times within 1 5 seconds to enter the exclusion mode Node ID has been excluded Reset Notice Use this procedure only in the event that the primary controller is lost or otherwise inoperable 1 Pressing TEST Button four times with...
Страница 8: ...nds 1 3 Z WaveTM Message Report When the smoke sensor detects the device will report the trigger event and also report the battery status In default the device will using Notification Report to represent the trigger event it can be changed to Sensor Binary Report by setting the configuration NO 7 Bit4 to 1 1 3 1 Smoke Detected Test Report When the Smoke Sensor detects smoke the device will unsolic...
Страница 9: ... to start the NWI mode Until timeout or the device successful to inclusion by controller NWI mode can be aborted by pressing the button 3 times 1 4 2 Wake When the device power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to save the battery energy 1 5 Over The Air OTA Firmware Update The device supp...
Страница 10: ...apidly and the controller will receive Smoke alarm test notification If the Smoke Sensor beeps three with yellow LED flashing three times in 43 seconds it indicates the Smoke Sensor is not working properly it requires to be repaired This is the only way to make sure that the Smoke Sensor device is working properly If the device fails to test properly have it repaired or replaced immediately If you...
Страница 11: ...chirp which indicates the device is receiving battery power 1 10 Choosing a Suitable Location For complete coverage in residential units Smoke Sensors should be installed in all rooms halls storage areas basements and attics in each family living unit Minimum coverage is one sensor on each floor and one in each sleeping area 1 Install Smoke Sensor as close to the center of ceiling as possible If t...
Страница 12: ...aters Do not install Smoke Sensors less than 20 feet 6 meters away from places where combustion particles are normally present like kitchens If a 20 foot distance is not possible e g in a mobile home try to install the alarm as far away from the combustion particles as possible preferably on the wall To prevent nuisance alarm alarms provide good ventilation in such places In very dusty or dirty ar...
Страница 13: ...s are aligned on the line In each of keyhole slots drawing a mark to locate a mounting plug and screw 4 Remove the bracket 5 Drill two holes at the marks and insert plastic wall plugs Put the Smoke Sensor away from plastic dust 6 Attach the bracket to the wall Line up the slots of the bracket and the Smoke Sensor Push the sensor onto the mounting bracket on turn it clockwise to fix it into the pla...
Страница 14: ...Using Notification Report 1 Using Sensor Binary Report Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 10 Auto Report Battery Time 12 0 127 The interval time for auto report the battery level 0 means turn off auto report battery Each tick means 30 minutes The default value is 12 6 hours 1 13 Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_...
Страница 15: ...27 MHz JP TW SI 104 921 40 MHz 919 80 MHz ANZ SI 104 869 00 MHz RU SI 104 865 20 MHz IN SI 104 IL 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight Operating Temperature 10oC 40oC For indoor use only Specifications subject to change without notice due to continuing product improvement OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 ...