SA-105
Dual Relay Touch Wall Switch
User Manual
Страница 1: ...SA 105 Dual Relay Touch Wall Switch User Manual ...
Страница 2: ...effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice This product contains some codes from GPL In compliance with GPL agreement AirLive will publish the GPL codes on our website Please go to www airlive com and go to the Support GPL men...
Страница 3: ...ipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cau...
Страница 4: ...r Manual Table of Contents 1 Overview 2 1 1 Adding to Z WaveTM Network 3 1 2 LED Indication 4 1 3 Choosing a Suitable Location 4 1 4 Installation and Basic Operation 5 1 5 Association and Parameter 7 1 6 Specifications 10 ...
Страница 5: ...e signal received to other modules in the system As part of a Z Wave network this switch will also act as a wireless repeater to insure that commands intended for another device in the network are received This is useful when the device would otherwise be out of the radio range of the Z Wave controller There are no field repairable assemblies on this unit If service was needed the unit must be ret...
Страница 6: ... been assigned a node ID and cannot work with Z Wave enabled devices The table below lists an operation summary of basic Z Wave function Please refer to the instructions for your Z Wave certificated primary controller to access the Setup function and to include exclude associate devices Note Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once...
Страница 7: ...iation 4 Use the Reset procedure only in the event that the network primary controller is missing or otherwise inoperable 1 2 LED Indication To distinguish what LED Color Led Display Status Description Blink 5 Times 1s Interval Light switch is powered on and has not been added to Z Wave network Blink 5 Times 500ms lnterval 1 Enter lnclusion Mode 2 Send Node lnfo Red Blink red color once then pink ...
Страница 8: ...diagram of SA 105 Note A Neutral wire is required for the correct operation Step 2 Removal of front cover Carefully use a flathead screw driver to remove the front cover from the base Do not use force as this could break the cover Output L1 Output L2 Live Wire Input Neutral Wire Input ...
Страница 9: ...t switch button turns the load attached to L2 ON OFF Caution Note Upon restoration of power after a power loss the switch returns to previous known state LED Indication The LED on the switch will change color when the load attached is turned on off Advance operation all on all off The switch support the all on all off commands The switch can be set to respond to all on and all off commands 4 diffe...
Страница 10: ...ICATION Notice The SWITCH_BINARY_REPORT is sent only by MULTI_CHANNEL_CMD_ENCAP command GROUP 2 Allows Sending Binary Switch Report to associated devices in this group This group is mapping to Endpoint 1 This Group Support SWITCH_BINARY_REPORT GROUP 3 Allows Sending Binary Switch Report to associated devices in this group This group is mapping to Endpoint 2 This Group Support SWITCH_BINARY_REPORT ...
Страница 11: ...is 1 This parameter defines the on off status of relay needs saving or not The status will be saved when relay status is changed if this parameter is set to 1 otherwise the relay status is not saved The Light Switch will restore the relay On Off status when is powered on again Root Device Mapped Setting Parameter NO 4 Length 1 Byte Valid values 0 3 default value is 1 This parameter defines which e...
Страница 12: ... of BASIC_SET 0x00 And BASIC_SET 0xFF are same as Binary Switch Command Class 1 5 5 Command Classes The root device of Light Switch supports Command Classes as Below COMMAND_CLASS_ZWAVEPLUS_INFO V21 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 COMMAND_CLASS_POWERLEVEL V1 COMMAND_CLASS_ASSOCIATION V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO V1 COMM...
Страница 13: ... 40M indoor 100m open space Supply Voltage 230 VAC Maximum Output Current 16A Resistive Load Maximum Output Power 2500 W Resistive Load LED Indicator 2 x LED one per button Dimension and Environment Dimensions 86 L x 86 W x 34 H mm Operating Temperature 0 40 C Specifications are subject to change and improvement without notice OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6...