SPECIFICATIONS

EXHAUST FANS

AK300LS

310 CFM/3.5 SONES @ 0.10" wg. • 290 CFM/3.5 SONES @ 0.25 wg.

HVI CERTIFIED 120 Volts, 0.75 amps, 60 hz.

Grill

White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 14

5/16

" x 14

5/16

".

• Blower Wheel

Balanced polymeric dual inlet blower wheel 6"  dia. x 5

3/8

" depth,

59 paddles, secured in place using 8M hex nut.

• Motor

Enclosed 4 pole electronically balanced permanently split
capacitor motor (PSC); life time lubrication, suitable for
continuous operation. Motor bearings - sleeve. Rated 115/120
volts, 60 Hz, 0.75 amps.

• Fan Housing

23 gauge galvanized steel housing.
Overall dimensions 12

7/8

"x 12

3/4

"x 9

7/8

".

• Duct Collar

6" round, zinc plated metal collar adapter. 6" spring loaded
aluminum backdraft damper.

• Ventilating Area

For bathrooms up to 310 sq. ft. For other rooms up to 385 sq. ft.

• Electrical Connections

1/2

" electrical knockouts provided. Easy wiring access via either

internal or external wiring compartment cover.

CUL/HVI

Canada:

 110 Glidden Road

Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015

U.S.:

 820 Lincoln Drive

West Chester, Pennsylvania  19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048

Updated 6-06

Specifications subject to change without notice.

• Unit Mounting

The housing will mount through drywall thickness up to 

3/4

",

with a rough-in opening of 13

1/8

" x 13". Rated for ceilings insulated

to R-40. The housing will mount either between 16" or 24" on
center joists, using the 2 supplied housing mounting brackets.
The housing mounting brackets can be adapted for overhead
mounting (hardware not provided). The unit is provided with an
optionally installed ceiling flange to ensure proper building
infiltration rates are maintained and that no air leaks occur
between the fan housing and ceiling cutout.

• Single Pack Shipping Info

Box Dim: 20" x 15

15/16

" x 11

3/8

"

UPC: 0-83162223002-7
Shipping Weight: 17 lbs.

C

US

PROJECT

LOCATION

CONTRACTOR

ARCHITECT

ENGINEER

SUBMITTED BY

DATE

FAN

MODEL

CFM

IN

RPM

WATTS

AMPS

SONES

QTY

OPTIONAL EQUIPMENT

NUMBER NUMBER

W.G.

& REMARKS

Acceptable for use over tub or shower when

installed in a GFCI protected branch circuit.

PERFORMANCE

HVI Sones

Fan Speed

Power

Static Pressure (inches of w.g.)

@ .1 SP

RPM

Watts

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

Air Flow - CFM

320

315

310

304

299

290

285

275

3.5

1200

80

9

7/8

"

6"

12

3/4

"

12

7/8

"

14

5/16

"

14

5/16

"