background image

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions

should always be followed to reduce the risk of fire,

electric shock and injury to person, including the following:

SAVE THESE INSTRUCTIONS

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO 

EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  This unit must be grounded.
f)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

g)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT 

USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.

 

a)  Acceptable for use over a bathtub or shower when installed in a 

GFCI protected branch circuit.

WARNING:

 DO NOT USE IN KITCHENS.

www.airkinglimited.com

A210952011 Rev. A 8-12

1 of 12

Exhaust Fan

Models: AK100D

Содержание AK100D

Страница 1: ...tallation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper...

Страница 2: ...other hidden utilities Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Fig...

Страница 3: ...ange between high and low Figure 9 NOTE Unit must be grounded according to all local and national codes 4 Reinstall both the wire compartment cover and the fan s venturi by reversing the instructions...

Страница 4: ...ot cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL W...

Страница 5: ...4 9 1 Motor Plate 5S2202005 10 1 Venturi 5S2202006 11 1 Screw 5S1999009 12 1 Screw 5S1999010 Qty Description Replacement Part 13 1 10 Ground Screw 5S1999002 14 1 14 ga Ground Wire 5S1999003 15 2 Grill...

Страница 6: ...www airkinglimited com A210952011 Rev A 8 12 6 of 12 NOTES...

Страница 7: ...s personne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et...

Страница 8: ...r le ch ssis et positionner le ch ssis dans le trou perc pr c demment afin qu il soit effleurement avec le plafond fini Fixer les extr mit s des traverses aux solives Figure 2 www airkinglimited com A...

Страница 9: ...re du compartiment du fil et le venturi du ventilateur en suivant les instructions la r verse l tape 1B de la section 5 du c blage Assurez vous que tous les fils sont contenus l int rieur du compartim...

Страница 10: ...aise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King p...

Страница 11: ...e Moteur 5S2202005 10 1 Venturi 5S2202006 11 1 Vis 5S1999009 12 1 Vis 5S1999010 de pi ce Qte Description de remplacement 13 1 Vis 10 de mise la terre 5S1999002 14 1 Fil de mise la terre de calibre 14...

Страница 12: ...www airkinglimited com A210952011 Rev A 8 12 12 of 12 REMARQUE...

Отзывы: