37
Mounting the Remote Sensor (Wireless)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
1.
Disconnect the controller wire from the side of Wine Guardian
unit and save for future use.
2.
Plan on mounting the remote sensor on a solid surface away
from doors, corners, air outlets, drafts or heat generating
equipment. Do not mount the remote sensor directly on an
outside wall, wall adjacent to a boiler room, or other hot area as
this runs the risk of influencing its temperature readings. The
recommended height is 5ft to 6ft (1.5m to 1.8m) above the
finished floor.
3.
Remove the sensor face plate (Fig. 1). Mark the mounting
points at the desired location within the wine cellar (Fig. 2).
4.
Drill two
1/8” holes and insert anchors within the mounting
surface. Anchors may not be required if securing to a wall stud
or racking system. Insert screws to secure the sensor to the
wall to ensure it mounts easily onto the two screws and slides
down onto the slotted openings freely.
5.
Input the three AA batteries. (Fig. 3)
(Only applicable with wireless installations)
6.
Pair the sensor with the unit
(See Page 38 for Pairing Instructions)
Note
: Once Paired the Remote Interface’s readings will be
included into the system’s temperature and humidity
averages.
7.
Mount the Remote Sensor on the wall (Fig. 4)
8.
Reattach the sensor’s faceplate (Fig. 5)
Содержание WINE GUARDIAN DS025
Страница 13: ...13 Overview of the Evaporator Fig 1...
Страница 14: ...14 Overview of the Condenser Fig 2...
Страница 15: ...15 Refrigeration Illustration Fig 3...
Страница 16: ...16 Wiring Diagram for DS025 WGS40 Fig 4...
Страница 17: ...17 Wiring Diagram for DS025 WGS40 cont Fig 5...
Страница 18: ...18 Wiring Diagram for DS025 WGS40 cont Fig 6...
Страница 19: ...19 Wiring Diagram for DS025 WGS40 cont Fig 7...